Read Harman Kardon ABH-4 (serv.man10) EMC - CB Certificate online
page 6 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
1.7
Marking and instructions
Pass
1.7.1
Rated voltage (V) ................................................: Input rating: 120-240V ac,
Output rating: 24V dc, 4A
Pass
Symbol of nature of supply for d.c. .......................:
Mains from AC source
N/A
Rated frequency (Hz) ..........................................: 50/60 Hz
N/A
Rated current (A) ................................................: 3 A.
Pass
Manufacturer ......................................................: SALOM ELECTRIC
(THAILAND) CO LTD
Pass
Trademark ..........................................................:
or
Pass
Type/model ........................................................: PS6 or SSB-0124
Pass
Symbol of Class II ...............................................: The equipment is regarded as
Class I
N/A
Certification marks ..............................................: CE, UL
Pass
1.7.2
Safety instructions
Operating/safety instructions
made available to the user.
made available to the user.
Pass
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N/A
1.7.4
Marking for voltage setting/frequency setting ........: Equipment is full ranging.
N/A
1.7.5
Marking at power outlets .....................................: No standard power outlets are
provided.
N/A
1.7.6
Marking at fuseholders ........................................: T3.15A, 250V
Pass
1.7.7
Wiring terminals
See below.
Pass
1.7.7.1
Protective earthing terminals
Appliance inlet is provided.
N/A
1.7.7.2
Terminal for external primary power supply
conductors
conductors
N/A
1.7.8.1
Identification, location and marking ................... :
N/A
1.7.8.2
Colours ........................................................... :
N/A
1.7.8.3
Symbols according to IEC 60417 ...................... :
N/A
1.7.8.4
Markings using figures .................................... : Figures are not used for
indicating different positions of
controls.
controls.
N/A
1.7.9
Isolation of multiple power sources ................... : There is only one connection
to hazardous voltages.
N/A
1.7.10
IT power system
Not intended for use on IT
power systems.
power systems.
N/A
Click on the first or last page to see other ABH-4 (serv.man10) service manuals if exist.