Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
2
PROTECTION FROM HAZARDS
Pass
2.1
Protection from electric shock and energy hazards
Pass
2.1.1
Protection in OPERATOR access areas
The construction of this plastic
enclosure prevents the
accessibility to any parts with
only basic insulation to ELV or
hazardous voltage with test
pin or test finger.
enclosure prevents the
accessibility to any parts with
only basic insulation to ELV or
hazardous voltage with test
pin or test finger.
Pass
2.1.1.1
Access to energized parts
The operator has access to
bare parts of SELV
CIRCUITS.
bare parts of SELV
CIRCUITS.
No operator access to
energized parts.
energized parts.
Pass
Test by inspection ............................................ : Operator cannot contact with
any parts with only basic
insulation to ELV or
hazardous voltage.
insulation to ELV or
hazardous voltage.
Pass
Test with test finger .......................................... : The test finger was unable to
contact bare hazardous parts,
basic insulation, or ELV
circuits.
basic insulation, or ELV
circuits.
Pass
Test with test pin .............................................. : The test pin was unable to
contact bare hazardous parts.
Pass
Test with test probe .......................................... : No TNV present.
N/A
2.1.1.2
Battery compartments ....................................... : No battery components.
N/A
2.1.1.3
Access to ELV wiring
Internal wiring in an ELV
circuit is not user accessible.
circuit is not user accessible.
N/A
Working voltage (V); distance (mm) through
insulation
insulation
2.1.1.4
Access to hazardous voltage circuit wiring
No internal wiring accessible
to the user.
to the user.
N/A
2.1.1.5
Energy hazards ................................................ : No hazardous voltage wiring
in operator accessible area.
Pass
2.1.1.6
Manual controls
No shafts or knobs, etc. at
ELV, TNV or hazardous
voltage.
ELV, TNV or hazardous
voltage.
N/A
2.1.1.7
Discharge of capacitors in the primary circuit
No risk of electric shock.
Pass
Time-constant (s); measured voltage (V) ........... : See enclosed test record.
2.1.2
Protection in service access areas
No bare parts operating at
HAZARDOUS VOLTAGES in
a service access area.
HAZARDOUS VOLTAGES in
a service access area.
N/A
2.1.3
Protection in restricted access locations
The unit is not intended to be
used in restricted locations.
used in restricted locations.
N/A