1) Dress the DY connector & connector assy,
5P with purse lock Ø5 (1x) as shown.
1) Install HV Cable Holder to HV Lead assy.
DISTANCE :
210 ± 5mm
210 ± 5mm
Purse Lock Ø5
Conn. Assy 5P
CN801( A PWB)
CN801( A PWB)
DY800 (A PWB)
DY
CN703 (C /CVPWB)
>10mm
HV Cable Combi, Holder
210 ± 5 mm
Installation of HV Cable Holder
HV Cable Holder must be parellal with
Coil DY as shown.
Coil DY as shown.
Keep a distance of 1mm/kV or more
--->TVSR: Spacing between HV cable
--->TVSR: Spacing between HV cable
and conductive part surface
Keep a distance of 0.5mm/kV or more
---> TVSR: Spacing between HV cable
---> TVSR: Spacing between HV cable
and conductive part surface
CAUTION:
Keep DY conn. in vertical during
dress together with conn. 5P
Keep DY conn. in vertical during
dress together with conn. 5P
TVSR REQUIREMENT :
1) Make sure the distance between
connector to FBT and all other high
voltage parts is more than 10mm.
1) Make sure the distance between
connector to FBT and all other high
voltage parts is more than 10mm.
TVSR REQUIREMENT :
HV Lead must be kept away from conductive
parts 1 mm/kV minimum is 30mm.
HV Lead must be kept away from conductive
parts 1 mm/kV minimum is 30mm.
CAUTION:
The height of the purse lock must be
straight with heatsink height to avoid
connector touching with FBT.
The height of the purse lock must be
straight with heatsink height to avoid
connector touching with FBT.
CAUTION:
Make sure the specified position
is being followed to avoid HV Lead
from touching rear cover, heat sink
at CV/C PWB & DY.
Make sure the specified position
is being followed to avoid HV Lead
from touching rear cover, heat sink
at CV/C PWB & DY.
Purse Lock Ø5
Conn. Assy 5P
CN801( A PWB)
CN801( A PWB)
FBT
DY 800 Conn.
SAFETY
OPERATION
2-7. Dress Connector DY & Connector Assy 5P with Purse Lock Ø5