KV-HG21M85 - Sony TV Service Manual (repair manual). Page 11

Read Sony KV-HG21M85 Service Manual online

– 10 –
KV-HG21M81/HG21M85
   RM-GA002
1) Dress the DY connector & connector assy,
 
5P with purse lock Ø5 (1x) as shown.
1) Install HV Cable Holder to HV Lead assy. 
DISTANCE :
210 ± 5mm
Purse Lock Ø5
Conn. Assy 5P
CN801( A PWB)
DY800 (A PWB)
DY
CN703 (C /CVPWB)
>10mm
HV Cable Combi, Holder
210 ± 5 mm
Installation of HV Cable Holder
HV Cable Holder must be parellal with
Coil DY as shown.
Keep a distance of 1mm/kV or more
--->TVSR: Spacing between HV cable
 
and conductive part surface
Keep a distance of 0.5mm/kV or more
---> TVSR: Spacing between HV cable
 
and conductive part surface
CAUTION:
Keep DY conn. in vertical during
dress together with conn. 5P
TVSR REQUIREMENT :
1) Make sure the distance between
  connector to FBT and all other high
  voltage parts is more than 10mm.
TVSR REQUIREMENT :
HV Lead must be kept away from conductive 
parts 1 mm/kV minimum is 30mm.
CAUTION:
The height of the purse lock must be
straight with heatsink height to avoid
connector touching with FBT.
CAUTION:
Make sure the specified position
is being followed to avoid HV Lead
from touching rear cover, heat sink
at CV/C PWB & DY.
Purse Lock  Ø5
Conn. Assy 5P
CN801( A PWB)
FBT
DY 800 Conn.
SAFETY
OPERATION
2-7.  Dress Connector DY & Connector Assy 5P with Purse Lock Ø5
2-8.  Install HV Cable Holder to HV Lead Assy
SAFETY
OPERATION
Page of 69