1-5
HDR-CX400E/CX410VE/CX430V/CX430VE/CX510E/PJ420E/PJ420VE/PJ430/PJ430E/PJ430V/PJ430VE/PJ510E_L2
– ENGLISH –
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
9
4
0
1
Internal flash memory fault
IM Model:
Inspect the flash memory (IC8101 on the MM-102 board).
E
9
4
0
2
BGM data error
Check the CPU (IC1301 on the VC-1012 board).
E
9
5
0
0
GPS hardware error
GPS Model:
Check whether the FFC-254 flexible flat cable is broken, and check 
whether it is inserted imperfectly.
If there is no problem the flexible board, inspect or replacement of 
the GP-037 board.
E
9
6
0
0
Map area mount error
GPS Model:
Inspect or replacement of the MM-102 board.
E
9
7
0
0
Projector  hardware error
Turn power off and turn power on again.
1-5.  METHOD OF COPING WITH SHIFT LENS ERROR
VC-1012 BOARD (SIDE A)
IC5601
C5636
C5640
C5642
C5643
R5632
Fig. 1
Measurement points on the VC-1012 board
approx. 330 msec
Note: The length of low section will vary a little depending on the conditions.
Fig. 2
Change in output voltage of R5632 on the VC-1012 board
1-5-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R5632 in the periphery of IC5601 on the VC-1012 board, turn the 
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect 
the camera control circuit (IC1301 of VC-1012 board) periphery.
Note:  When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-5-2. E : 62 : 11 [Shift Lens Overheating (Pitch)] Occurred 
Order
AdjustBlock
AdjustCode
Order
1
Start the Adjust Manual in the Adjust Station and execute the [Measure to E:62:11/12] on the 
[SERVICE] tab.
2
Check if the shift lens moves while setting the order 1.
If the shift lens does not move, replace the lens block (Note).
When the shift lens moved, proceed to the order 3.
3
While setting the order 1, measure with an oscilloscope the output voltage of C5642 and C5643 in 
the periphery of IC5601 on the VC-1012 board to check the output voltage varies.
4
If the output voltage does not vary, replace the lens block (Note).
When the output voltage varied, proceed to the order 5.
5
Turn the power OFF.
6
While measuring with an oscilloscope the output voltage of R5632 in the periphery of IC5601 on the 
VC-1012 board, turn the power ON to check that the output voltage immediately after the power on 
change as shown in Fig. 2.
7
If the output voltage rises to 3V, replace the lens block (Note).
If it does not rises to 3V, inspect the camera control circuit IC1301 and IC5601 on the VC-1012 
board periphery.
Note:  When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
 
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
Page of 41