DEV-3, DEV-5 (serv.man2) - Sony Movie Service Manual (repair manual). Page 7

Read Sony DEV-3 / DEV-5 (serv.man2) Service Manual online

DEV-3/5_L2
1-3
– ENGLISH –
1-7.  METHOD OF COPING WITH SHIFT LENS ERROR
LD-286 BOARD (SIDE A)
LD-286 BOARD (SIDE B)
C5527 
C5528
C5525
C5526
C5529
C5530
C5531
C5532
R5506
IC5501
C5527
C5528
C5525
C5526
C5529
C5530
C5531
C5532
R5506
IC5501
Fig. 1
Measurement points on the LD-286 board
about 330 msec
Note: The length of low section will vary a little depending on the conditions.
Fig. 2
Change in output voltage of R5506 on the LD-286 board
1-7-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R5506 in the periphery of IC5501 on the LD-286 board, turn the 
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens device (Note). If it does not change as shown in Fig. 2, inspect 
the camera control circuit (IC1301 of VC-642 board) periphery.
Note:  When the lens device was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-7-2. E : 62 : 11 [Shift Lens Overheating (Pitch)] Occurred
Connect by the SeusEX and perform the following process.
Order
AdjustBlock
AdjustCode
Procedure
0
Perform the following process in movie mode.
1
0404
A_TB_HLL_2E
00000001, 00000000, 
00000000, 00000000
Write the data. (After it starts, set it before caution is displayed.)
2
Check if the shift lens moves while setting the order 1.
If the shift lens does not move, replace the lens device (Note).
When the shift lens moved, proceed to the order 3.
3
While setting the order 1, measure with an oscilloscope the output voltage 
of C5529 and C5530 in the periphery of IC5501 on the LD-286 board to 
check the output voltage varies.
4
If the output voltage does not vary, replace the lens device (Note).
When the output voltage varied, proceed to the order 5.
5
0404
A_TB_HLL_2E
00000000, 00000000, 
00000000, 00000000
Write the data. (After it starts, set it before caution is displayed.)
6
Check if the shift lens moves while setting the order 5.
If the shift lens does not move, replace the lens device (Note).
When the shift lens moved, proceed to the order 7.
7
While setting the order 5, measure with an oscilloscope the output voltage 
of C5525 and C5526 in the periphery of IC5501 on the LD-286 board to 
check the output voltage varies.
8
If the output voltage does not vary, replace the lens device (Note).
When the output voltage varied, proceed to the order 9.
9
Turn the power OFF.
10
While measuring with an oscilloscope the output voltage of R5506 in the 
periphery of IC5501 on the LD-286 board, turn the power ON to check 
that the output voltage immediately after the power on change as shown 
in Fig. 2.
11
If the output voltage change as shown in Fig. 2, replace the lens device 
(Note).
If it does not change as shown in Fig. 2, inspect the camera control circuit 
(IC1301 of VC-642 board and IC5501 of LD-286 board) periphery.
Note:  When the lens device was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
 
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
Page of 25
Display

Click on the first or last page to see other DEV-3 / DEV-5 (serv.man2) service manuals if exist.