DCR-VX2200E (serv.man2) - Sony Movie Service Manual (repair manual). Page 64

Read Sony DCR-VX2200E (serv.man2) Service Manual online

6-63
DCR-VX2200E_ADJ
H
A
C
B
2-2. COMPONENT OUT Y Level Adjustment
(VC-597 board)
Mode
CAMERA mode
Subject
Arbitrary
Measurement Point
Y signal terminal of COMPONENT
OUT plug of A/V Remote connector
(75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
8C
Specified value
Y level: A = 1000 
± 10 mVp-p
Sync level: B = C = 300 
± 10 mVp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
7
83
02
3
3
71
01
Press PAUSE (Write) button.
4
0
10
01
5
8
5C
Set the bit value of bit0 is
(18)
“1”, and press PAUSE
(Write) button. (Note)
6
8
5D
05
Press PAUSE (Write) button.
(18)
7
0
10
00
8
C
8C
Change the data and set the Y
signal level (A) to the
specified value.
8
C
8C
Press PAUSE (Write) button.
10
Check the sync signal (B, C)
to the specified value.
11
0
10
01
12
8
5C
Set the bit value of bit0 is
(18)
“0”, and press PAUSE
(Write) button. (Note)
13
8
5D
00
Press PAUSE (Write) button.
(18)
14
0
10
00
15
3
70
10
Press PAUSE (Write) button.
16
3
70
Check the data changes to
“11”.
17
7
83
00
18
0
01
00
Note:
For the bit values, refer to “6-4. SERVICE MODE”, “4-4.
3. Bit value discrimination”.
Fig. 6-3-6
2-3. COMPONENT OUT Pr Level Adjustment
(VC-597 board)
Mode
CAMERA mode
Subject
Arbitrary
Measurement Point
P
r
/C
r
 signal terminal of COMPO-
NENT OUT plug of A/V Remote
connector (75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
8E
Specified value
Pr level: A = 525 
± 10 mVp-p
Sync level: B = C = 300 
± 10 mVp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
7
83
02
3
3
71
01
Press PAUSE (Write) button.
4
0
10
01
5
8
5C
Set the bit value of bit0 is
(18)
“1”, and press PAUSE
(Write) button. (Note)
6
8
5D
05
Press PAUSE (Write) button.
(18)
7
0
10
00
8
C
8E
Change the data and set the
Pr signal level (A) to the
specified value.
9
C
8E
Press PAUSE (Write) button.
10
Check the sync signal (B, C)
to the specified value.
11
0
10
01
12
8
5C
Set the bit value of bit0 is
(18)
“0”, and press PAUSE
(Write) button. (Note)
13
8
5D
00
Press PAUSE (Write) button.
(18)
14
0
10
00
15
3
70
10
Press PAUSE (Write) button.
16
3
70
Check the data changes to
“11”.
17
7
83
00
18
0
01
00
Note:
For the bit values, refer to “6-4. SERVICE MODE”,
“4-4. 3. Bit value discrimination”.
Fig. 6-3-7
H
A
C
B
Page of 80
Display