DCR-VX2200E (serv.man2) - Sony Movie Service Manual (repair manual). Page 59

Read Sony DCR-VX2200E (serv.man2) Service Manual online

6-58
DCR-VX2200E_ADJ
3-3-4.  SD Error Rate Check (VC-597 board) 
RadarW
RadarW
RadarW
Note:
Check that the data of page: 0, address: 10 is “00”.
4-1. Preparations before adjustments
Mode
Camera recording (CAMERA mode)
Subject
Arbitrary
Switch setting
1) REC FORMAT (Menu setting) ......................................... DV
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
71
01
Press PAUSE (Write) button.
3
0
10
01
4
C
0D
CC
Press PAUSE (Write) button.
(1C)
5
0
10
00
6
3
1D
20
Press PAUSE (Write) button.
7
Record the camera signal for
2 minutes.
4-2. Error Rate Check
Mode
VTR playback (VCR mode)
Subject
Recorded signal at “Preparations
before adjustments”
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
B2 to C7
Specified value
The data of page: 3, address: 03 is
“00”
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Initial Value of Page C: Address: B2 to C7
Address
Initial
Address
Initial
Address
Initial
value
value
value
B2
00
BA
00
C2
80
B3
00
BB
00
C3
00
B4
00
BC
00
C4
00
B5
00
BD
00
C5
00
B6
00
BE
00
C6
00
B7
80
BF
00
C7
00
B8
00
C0
00
B9
00
C1
00
Table 6-3-4
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
71
01
Press PAUSE (Write) button.
3
Check that the data of page:
C, address: B2 to C7 is the
initial value. (See Table 6-3-
4)
4
Playback the recorded signal
at “Preparations before
adjustments”.
5
3
03
FF
Press PAUSE (Write) button.
6
3
01
40
Press PAUSE (Write) button.
7
3
02
Check the data changes to
“00”.
8
3
03
Check the data is “00”. (Note 2)
9
3
01
00
Press PAUSE (Write) button.
10
Perform “Processing after
Completing Adjustments”.
Note 2:
If the data is other than “00”, Error rate is abnormal.
For the contents of the abnormality, see the following
table.
Data of page: 3,
Contents of defect
address: 03
01
EVEN channel is abnormal.
02
ODD channel is abnormal.
03
EVEN channel and ODD channel are
abnormal.
Note 3:
If Error rate is abnormal, Check the use tape, clean the
tape running surface. And after inputting initial values to
page C: address: B2 to C7, perform re-adjustment. (See
Table 6-3-4)
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
01
3
C
0D
00
Press PAUSE (Write) button.
(1C)
4
0
10
00
5
3
70
10
Press PAUSE (Write) button.
6
3
70
Check the data changes to
“11”.
7
0
01
00
Page of 80
Display

Click on the first or last page to see other DCR-VX2200E (serv.man2) service manuals if exist.