DCR-VX2200E (serv.man2) - Sony Movie Service Manual (repair manual). Page 65

Read Sony DCR-VX2200E (serv.man2) Service Manual online

6-64
DCR-VX2200E_ADJ
H
A
C
B
Fig. 6-3-8
2-4. COMPONENT OUT Pb Level Adjustment
(VC-597 board)
Mode
CAMERA mode
Subject
Arbitrary
Measurement Point
P
b
/C
b
 signal terminal of COMPO-
NENT OUT plug of A/V Remote
connector (75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
8D
Specified value
Pb level: A = 525 
± 10 mVp-p
Sync level: B = C = 300 
± 10 mVp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
7
83
02
3
3
71
01
Press PAUSE (Write) button.
4
0
10
01
5
8
5C
Set the bit value of bit0 is
(18)
“1”, and press PAUSE
(Write) button. (Note)
6
8
5D
05
Press PAUSE (Write) button.
(18)
7
0
10
00
8
C
8D
Change the data and set the
Pb signal level (A) to the
specified value.
9
C
8D
Press PAUSE (Write) button.
10
Check the sync signal (B, C)
to the specified value.
11
0
10
01
12
8
5C
Set the bit value of bit0 is
(18)
“0”, and press PAUSE
(Write) button. (Note)
13
8
5D
00
Press PAUSE (Write) button.
(18)
14
0
10
00
15
3
70
10
Press PAUSE (Write) button.
16
3
70
Check the data changes to
“11”.
17
7
83
00
18
0
01
00
Note:
For the bit values, refer to “6-4. SERVICE MODE”, “4-4.
3. Bit value discrimination”.
2-5. Processing after Complete Adjustment
Note:
After the “COMPONENT VIDEO OUT Adjustment”, be
sure to set to normal mode.
Perform the following data setting.
Order Page Address Data
Procedure
1
07
01
D1
2
07
04
00
3
07
02
FF
4
07
00
01
Press PAUSE (Write) button.
5
07
02
Check the data is “01”.
6
07
01
BD
7
07
04
01
8
07
02
FF
9
07
00
01
Press PAUSE (Write) button.
10
07
02
Check the data is “01”.
11
00
01
00
12
Reset the hardware.
Page of 80
Display

Click on the first or last page to see other DCR-VX2200E (serv.man2) service manuals if exist.