6-61
DCR-VX2200E_ADJ
1-3. S VIDEO OUT Chroma Level Adjustment
(VC-597 board)
Mode
VCR mode
Signal
No signal
Measurement Point
Chroma signal terminal of S VIDEO
plug of A/V Remote connector (75
Ω terminated)
External trigger: Y signal terminal of
S VIDEO plug of A/V Remote
connector (75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
7F, 80
  Specified value
Cr level: A = 700 
± 14 mVp-p
Cb level: B = 700 
± 14 mVp-p
Burst level: C = 300 
± 6 mVp-p
Adjusting method for NTSC model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
26
Change the data and set the
Cr signal level (A) to the
specified value.
3
C
26
Press PAUSE (Write) button.
4
C
7F
Set a value obtained by
subtracting 5 from the
fore mentioned data, and
press PAUSE (Write) button.
5
C
27
Change the data and set the
Cb signal level (B) to the
specified value.
6
C
27
Press PAUSE (Write) button.
7
C
80
Set a value obtained by
subtracting 3 from the
fore mentioned data, and
press PAUSE (Write) button.
8
Check the burst signal (C) to
the specified value.
9
Perform “Processing after
Complete Adjustment”.
Fig. 6-3-4
Adjusting method for PAL model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
7F
Change the data and set the
Cr signal level (A) to the
specified value.
3
C
7F
Press PAUSE (Write) button.
4
C
26
Set a value obtained by
adding 5 to the
fore mentioned data, and
press PAUSE (Write) button.
5
C
80
Change the data and set the
Cb signal level (B) to the
specified value.
6
C
80
Press PAUSE (Write) button.
7
C
27
Set a value obtained by
adding 3 to the
fore mentioned data, and
press PAUSE (Write) button.
8
Check the burst signal (C) to
the specified value.
9
Perform “Processing after
Complete Adjustment”.
H
A
B
0.23 
μ
sec
0.23 
μ
sec
C
Page of 80
Display