Read Sony DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) Service Manual online
DCR-TRV940/TRV940E/TRV950/TRV950E
6-10
2.
Modification of A, D Page Data
If the A, D page data has been initialized, change the data of
the“Fixed data-2” address shown in the following table by manual
input.
the“Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
the data built in the same model.
Note 1:
If copy the data built in the different model, the
camcorder may not operate.
camcorder may not operate.
3) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification A, D page data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
Note 2:
If the following symptoms occur after completing of
the“Modification A, D page data”, check that the data of
the “Fixed data-2” addresses of A, D page are same as
those of the same model of the same destination.
1) “E: 20: 00” of self-diagnosis code on LCD screen is
the“Modification A, D page data”, check that the data of
the “Fixed data-2” addresses of A, D page are same as
those of the same model of the same destination.
1) “E: 20: 00” of self-diagnosis code on LCD screen is
flashing.
2) The power is shut off so that unit cannot operate.
1-2-1.
Initialization of A, D Page Data
Note:
Check that the data of page: 0, address: 10 is “00”.
1.
Initializing of A, D Page Data
Note 1:
If the A, D page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, D page data
2) Touch panel adjustment
adjustments need to be performed again.
1) Modification of A, D page data
2) Touch panel adjustment
Note 2:
Check that the voltage of power supply is 6.0
±
0.1Vdc.
Note 3:
NTSC model: DCR-TRV940/TRV950
PAL model: DCR-TRV940E/TRV950E
PAL model: DCR-TRV940E/TRV950E
Adjustment Page
A
Adjustment Address
10 to FF
Adjustment Page
D
Adjustment Address
10 to 7F
A page initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
7
03
Set the following data
07: NTSC model
87: PAL model
07: NTSC model
87: PAL model
4
7
00
20
5
7
01
20
Press PAUSE button.
6
7
02
Check the data changes to
“01”.
“01”.
7
2
00
29
8
2
01
29
Press PAUSE button.
9
Perform “Modification of A,
D Page Data”
D Page Data”
D page initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
7
03
Set the following data
07: NTSC model
87: PAL model
07: NTSC model
87: PAL model
4
7
00
22
5
7
01
22
Press PAUSE button.
6
7
02
Check the data changes to
“01”.
“01”.
7
2
00
29
8
2
01
29
Press PAUSE button.
9
Perform “Modification of A,
D Page Data”
D Page Data”
Click on the first or last page to see other DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) service manuals if exist.