DCR-TRV940/TRV940E/TRV950/TRV950E
6-5
Fig. 6-1-2
1-1-2.
Preparations
Note 1:
For details of how remove the cabinet and boards, refer
to “2. DISASSEMBLY”.
Note 2:
When performing only the adjustments, the lens block
and boards need not be disassembled.
Note 3:
Before perform the adjustment, check that the data of
page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set data “00”.
1) Connect the equipment for adjustments according to
Fig. 6-1-3.
Note 4:
As removing the cabinet (R) (removing the CK-116 board
CN5203) means removing the lithium 3V power supply
(BT5201), data such as date, time, user-set menus will
be lost. After completing adjustments, reset these data.
If the NS-014 board has been removed, the self-diagno-
sis data, data on history of use (total drum rotation time,
etc. ) will not be lost. (Refer to “SELF-DIAGNOSIS
FUNCTION” for the self-diagnosis data, and to “6-4.
Service Mode” for the data on the history use)
Note 5:
Setting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press
the PAUSE button of the adjustment remote com-
mander.
The above procedure will enable the camera power
to be turned on with the power switch (PS-1870 block)
removed. After completing adjustments, be sure to
exit the “Forced Camera Power ON Mode”.
Note 6:
Exiting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote com-
mander.
3) Select page: 0, address: 01, and set data: 00.