Read Sony DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) Service Manual online
DCR-TRV940/TRV940E/TRV950/TRV950E
6-9
COVER
COVER
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 1B,
1E, 1F PAGE DATA
1E, 1F PAGE DATA
Note 1:
If reading/writing data on pages 1B, 1E, 1F, set data: 01
to page: 0, address: 10, and then select pages B, E, F. By
this data setting, the pages 1B, 1E, 1F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
to page: 0, address: 10, and then select pages B, E, F. By
this data setting, the pages 1B, 1E, 1F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
[Connection of power supply for data initialization]
1) Connect the regulated power supply and a digital voltmeter, as
shown in Fig. 6-1-8.
2) Adjust the output voltage of the regulated power supply so
that the digital voltmeter indicates 6.0
±
0.1Vdc.
3) Turn off the power switch.
4) Turn on the HOLD switch of the adjusting remote commander.
5) Turn on the power switch.
6) Initialize the data.
4) Turn on the HOLD switch of the adjusting remote commander.
5) Turn on the power switch.
6) Initialize the data.
Note 2:
Though the following message will be displayed on the
LCD screen, this is normal.
“Use info lithium battery”
LCD screen, this is normal.
“Use info lithium battery”
Fig. 6-1-8
[Adjusting Procedure]
1. Initialaizing of A, D Page Data
2. Initialaizing of 8, C Page Data
3. Initialaizing of E, F, 1E, 1F Page Data
4. Initialaizing of B, 1B Page Data
2. Initialaizing of 8, C Page Data
3. Initialaizing of E, F, 1E, 1F Page Data
4. Initialaizing of B, 1B Page Data
Regulated power supply
6.0
6.0
±
0.1 Vdc
Digital voltmeter
Click on the first or last page to see other DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) service manuals if exist.