Read Sony DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) Service Manual online
DCR-TRV940/TRV940E/TRV950/TRV950E
6-12
1-2-2.
Initialization of 8, C Page Data
Note:
Check that the data of page: 0, address: 10 is “00”.
1.
Initializing of 8, C Page Data
Note1:
If “Initialization of Pages 8, C” is executed, all data on
pages 8, C are initialized. (Only an individual page can-
not be initialized)
pages 8, C are initialized. (Only an individual page can-
not be initialized)
Note 2:
If the 8, C page data has been initialized, the following
adjustments need to be performed again.
1) Modification of 8, C page data
2) Color electronic viewfinder system adjustments
3) LCD system adjustments
4) Node unique ID No. input
5) Servo, RF system adjustments
6) Video system adjustments
adjustments need to be performed again.
1) Modification of 8, C page data
2) Color electronic viewfinder system adjustments
3) LCD system adjustments
4) Node unique ID No. input
5) Servo, RF system adjustments
6) Video system adjustments
Note 3:
Check that the voltage of power supply is 6.0
±
0.1Vdc.
Adjustment Page
8
Adjustment Address
00 to A3
Adjustment Page
C
Adjustment Address
10 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
81
Check the data changes to
“00”.
“00”.
4
3
80
0C
Press PAUSE button.
5
3
80
Check the data changes to
“1C”.
“1C”.
6
Perform “Modification of 8,
C Page Data”
C Page Data”
2.
Modification of 8, C Page Data
If the 8, C page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual
input.
“Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder
may not operate.
the data built in the same model.
Note: If copy the data built in the different model, the camcorder
may not operate.
3) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification 8, C page data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
Click on the first or last page to see other DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) service manuals if exist.