DCR-TRV940, DCR-TRV940E, DCR-TRV950, DCR-TRV950E (serv.man4) - Sony Movie Service Manual (repair manual). Page 15

Read Sony DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) Service Manual online

DCR-TRV940/TRV940E/TRV950/TRV950E
6-12
1-2-2.
Initialization of 8, C Page Data
Note:
 Check that the data of page: 0, address: 10 is “00”.
1.
Initializing of 8, C Page Data
Note1:
If “Initialization of Pages 8, C” is executed, all data on
pages 8, C are initialized. (Only an individual page can-
not be initialized)
Note 2:
If the 8, C page data has been initialized, the following
adjustments need to be performed again.
1) Modification of 8, C page data
2) Color electronic viewfinder system adjustments
3) LCD system adjustments
4) Node unique ID No. input
5) Servo, RF system adjustments
6) Video system adjustments
Note 3:
Check that the voltage of power supply is 6.0 
±
 0.1Vdc.
Adjustment Page
8
Adjustment Address
00 to A3
Adjustment Page
C
Adjustment Address
10 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
81
Check the data changes to
“00”.
4
3
80
0C
Press PAUSE button.
5
3
80
Check the data changes to
“1C”.
6
Perform “Modification of 8,
C Page Data”
2.
Modification of 8, C Page Data
If the 8, C page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder
may not operate.
3) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification 8, C page data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
Page of 78
Display

Click on the first or last page to see other DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) service manuals if exist.