6-35
DCR-SR30E/SR40/SR40E_ADJ
5) If the 
[End]
 button is clicked, the following screen is displayed
during the execution of “4. Transmissive Mode White Balance
Adj.”. Check that the LCD screen is not colored. If colored,
using the 
[Up]
 / 
[Down]
 button on the screen, adjust so that
the LCD screen is not colored. After the adjustment, click the
[End]
 button in the screen.
6) If the 
[End]
 button is clicked, “5. Release of Data Setting dur-
ing LCD Adj.” will be executed.
7) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the 
[OK]
 button.
3.
LCD Adjustment
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD Adj.
2. LCD Automatic Adj.
(VCO Adj., Contrast Adj.)
3. V-COM Adj.
4. Transmissive Mode White Balance Adj.
5. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Select the model with the Model Select radio button.
Note:
NTSC model: DCR-SR40
PAL model: DCR-SR30E/SR40E
2) Click the 
[Start]
 button of the LCD Adjustment.
3) The Automatic Adjustment Program executes the “1. Data
Setting during LCD Adj.” and “2. LCD Automatic Adj.”.
4) After that, the following screen is displayed during the execu-
tion of “3. V-COM Adj.”. Using the 
[Up]
 / 
[Down]
 button on
the screen, adjust so that the brightness of portions A and B on
the LCD panel is equal. After the adjustment, click the 
[End]
button in the screen.