DCR-PC10, DCR-PC10E - Sony Movie Service Manual (repair manual). Page 127

Read Sony DCR-PC10 / DCR-PC10E Service Manual online

5-55
3-5-3.
Clock Adjustment
1. IC1900 27MHz XTAL fo adjustment (VC-199 Board)
Set the sub-carrier frequency of the video output signal in VTR
mode.
Mode
VTR stop
Signal
No signal
Measurement Point
R1901 (Pin 2 of IC1900)
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
98
Specified Value
f = 13500000 ± 50 Hz (NTSC)
f = 13500000 ± 50 Hz (PAL)
Adjustment procedure:
Order
Page
Address
Data
Procedure
1
0
01
01
Set the data.  (Preparation)
2
D
98
Change the data until the clock frequency (f) satisfies the specification value.
3
Press the PAUSE button.
4
0
01
00
Set the data.  (End)
Page of 127
Display

Download Sony DCR-PC10 / DCR-PC10E Service Manual (Repair Manual)