DCR-PC10, DCR-PC10E - Sony Movie Service Manual (repair manual). Page 118

Read Sony DCR-PC10 / DCR-PC10E Service Manual online

5-46
2. Switching Position Adjustment (MR-39 Board)
Mode
Playback
Signal
SW/OL reference tape
Measurement Point
Display data of page: 3, address: 03 of
Measuring Instrument
the adjustment remote commander.
Adjustment Page
C
Adjustment Address
4C, 4D, 4E, 4F
Specified Value
00
Adjustment procedure:
Order
Page
Address
Data
Procedure
1
0
01
01
Set the data. (Preparation)
2
Playback the SW/OL reference tape in VTR mode.
3
3
01
0E
After setting the data, press the PAUSE button.
4
3
02
Check that the data of page: 3, address: 02 has changed from 0E to 00.
5
3
03
Check that the data pf page: 3, address: 03 is 00.
6
Set the HOLD switch of the adjustment remote commander to OFF, and wait more than 2
seconds (so that the adjustment data is automatically written is page: C, addresses: 4C to 4F.)
7
0
01
00
Set the data.
8
Push EJECT button to take the SW/OL reference tape out.
9
Turn OFF the power switch.
Page of 127
Display