DCR-HC51E, DCR-HC52, DCR-HC52E, DCR-HC53E, DCR-HC54, DCR-HC54E (serv.man4) - Sony Movie Service Manual (repair manual). Page 42

Read Sony DCR-HC51E / DCR-HC52 / DCR-HC52E / DCR-HC53E / DCR-HC54 / DCR-HC54E (serv.man4) Service Manual online

6-41
DCR-HC51E/HC52/HC52E/HC53E/HC54/HC54E_ADJ
3.
 SD Error Rate Check (LP)  (VC-537 board)
RadarW
RadarW
RadarW
RadarW
RadarW
Note: Check that the data of page: 0, address: 10 is “00”.
3-1. Preparations before adjustments
  Mode
Camera recording
(CAMERA mode)
Subject
Arbitrary
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
01
3
C
0D
C8
Press PAUSE (Write) button.
4
0
10
00
5
Record the camera signal for
2 minutes.
3-2. Error Rate Check
Mode
VTR playback (PLAY/EDIT mode)
Subject
Recorded signal at “Preparations
before adjustments”
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjusting remote commander
Adjustment Page
1C  (Note 1)
Adjustment Address
B3 to C8
Specified value
The data of page: 3, address: 03 is
“00”
Note 1: If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Initial Value of Page 1C: Address: B3 to C8
Address
Initial
Address
Initial
Address
Initial
value
value
value
B3
00
BB
00
C3
80
B4
00
BC
00
C4
00
B5
00
BD
00
C5
00
B6
00
BE
00
C6
00
B7
00
BF
00
C7
00
B8
80
C0
00
C8
00
B9
00
C1
00
BA
00
C2
00
Table 6-3-4
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Check that the data of page:
1C, address: B3 to C8 is the
initial value. (See Table 6-3-
4)
3
Playback the recorded signal
at “Preparations before
adjustments”.
4
3
03
FF
Press PAUSE (Write) button.
5
3
01
40
Press PAUSE (Write) button.
6
3
02
Check the data changes to
“00”.
7
3
03
Check the data is “00”. (Note 2)
8
Perform “Processing after
Completing Adjustments”.
Note 2: If the data is other than “00”, Error rate is abnormal.
For the contents of the abnormality, see the following
table.
Data of page: 3,
Contents of defect
address: 03
01
EVEN channel is abnormal.
02
ODD channel is abnormal.
03
EVEN channel and ODD channel are
abnormal.
Note 3: If Error rate is abnormal, Check the use tape, clean the
tape running surface. And after inputting initial values to
page 1C: address: B3 to C8, perform re-adjustment. (See
Table 6-3-4)
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
01
3
C
0D
00
Press PAUSE (Write) button.
4
0
10
00
5
0
01
00