6-39
DCR-HC51E/HC52/HC52E/HC53E/HC54/HC54E_ADJ
3-3.
SERVO  AND  RF  SYSTEM  ADJUSTMENTS
Before perform the servo and RF system adjustments, check that
the specified values of “36MHz Origin Oscillation Adjustment”
of “1-3. CAMERA SYSTEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”. If not, select
page: 0, address: 10, and set the data “00”.
Adjusting Procedure:
1. CAP FG duty adjustment
2. Switching position adjustment
3. SD Error rate check (LP)
1.
CAP FG Duty Adjustment (VC-537 board)
RadarW
RadarW
RadarW
RadarW
RadarW
Set the CAP FG signal duty cycle to 50% to establish an appropri-
ate capstan servo. If deviated, the uneven rotation of capstan and
noise can occur in the LP mode.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
16
Specified value
The data of page: 3, address: 03 is
“00”
Note 1: Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compart-
ment without inserting
cassette.
2
0
01
01
3
C
16
20
Press PAUSE (Write) button.
4
3
03
FF
Press PAUSE (Write) button.
5
3
01
1B
Press PAUSE (Write) button.
6
3
02
Check the data changes in
the following order
“1B” 
t “2B” t “00”
7
3
03
Check the data is “00”. (Note 2)
8
0
01
00
Note 2: If the data is “01” or “11”, adjustment has errors or the
mechanism deck is defective.
Also, if the data is “80”, the mechanism deck is in emer-
gency state or the tape reached its end.
Page of 62