Read Sony DCR-HC51E / DCR-HC52 / DCR-HC52E / DCR-HC53E / DCR-HC54 / DCR-HC54E (serv.man4) Service Manual online
6-39
DCR-HC51E/HC52/HC52E/HC53E/HC54/HC54E_ADJ
3-3.
SERVO AND RF SYSTEM ADJUSTMENTS
Before perform the servo and RF system adjustments, check that
the specified values of “36MHz Origin Oscillation Adjustment”
of “1-3. CAMERA SYSTEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”. If not, select
page: 0, address: 10, and set the data “00”.
the specified values of “36MHz Origin Oscillation Adjustment”
of “1-3. CAMERA SYSTEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”. If not, select
page: 0, address: 10, and set the data “00”.
Adjusting Procedure:
1. CAP FG duty adjustment
2. Switching position adjustment
3. SD Error rate check (LP)
1. CAP FG duty adjustment
2. Switching position adjustment
3. SD Error rate check (LP)
1.
CAP FG Duty Adjustment (VC-537 board)
RadarW
RadarW
RadarW
RadarW
RadarW
Set the CAP FG signal duty cycle to 50% to establish an appropri-
ate capstan servo. If deviated, the uneven rotation of capstan and
noise can occur in the LP mode.
ate capstan servo. If deviated, the uneven rotation of capstan and
noise can occur in the LP mode.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Displayed data of page: 3, address:
03
03
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
16
Specified value
The data of page: 3, address: 03 is
“00”
“00”
Note 1: Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compart-
ment without inserting
cassette.
ment without inserting
cassette.
2
0
01
01
3
C
16
20
Press PAUSE (Write) button.
4
3
03
FF
Press PAUSE (Write) button.
5
3
01
1B
Press PAUSE (Write) button.
6
3
02
Check the data changes in
the following order
“1B”
the following order
“1B”
t “2B” t “00”
7
3
03
Check the data is “00”. (Note 2)
8
0
01
00
Note 2: If the data is “01” or “11”, adjustment has errors or the
mechanism deck is defective.
Also, if the data is “80”, the mechanism deck is in emer-
gency state or the tape reached its end.
Also, if the data is “80”, the mechanism deck is in emer-
gency state or the tape reached its end.
Click on the first or last page to see other DCR-HC51E / DCR-HC52 / DCR-HC52E / DCR-HC53E / DCR-HC54 / DCR-HC54E (serv.man4) service manuals if exist.