Read Sony DVP-NW50 (serv.man2) Service Manual online
15
15
3-3. Control signal input
SYSTEM
CONTROLLER
(U1)
IR REMOTE
IR IN
(J7)
REMOTE
CONTROL
RECEIVER
(U1)
IR REMOTE
IR OUT
(J8)
PHYSICAL
LAYER
TRANSCEIVER
(U26)
NAND (U2),
TIMER (U25)
IR REMOTE
IR OUT
(J8)
TX signals
RX signals
TX+/TX-
RX+/RX-
KEY SW (S1-S23),
DECODER (U11)
Please refer to Block diagram on page 25 in the Service manual.
When SYSTEM CONTROLLER (U1) boots up, SYSTEM CONTROLLER starts to check
control inputs of four sources in DVP-NW50.
control inputs of four sources in DVP-NW50.
1. Key SW input on the set
DECODER (U11) converts the key input detection signal and output to SYSTEM
CONTROLLER (U1).
CONTROLLER (U1).
2. Wired IR REMOTE input
The input signal is wired SIRCS signal. The IR input signal is transferred to IR OUT terminal for
next device automatically.
next device automatically.
3. Remote commander input with Infrared signal
REMOTE CONTROL RECEIVER (U1) convert the Infrared signal to electrical signal.
4. Ethernet line input
The Ethernet line input is received and processed physically by PHYSICAL LAYER
TRANSCEIVER (U26). Then, the signal is transferred to SYSTEM CONTROL (U1) and
decoded logically.
TRANSCEIVER (U26). Then, the signal is transferred to SYSTEM CONTROL (U1) and
decoded logically.
While communicating with Ethernet line, one blue LED(D21) continue flashing by data
communication and two red LEDs are lit continuously.
communication and two red LEDs are lit continuously.