DVP-NW50 (serv.man2) - Sony DVD Service Manual (repair manual). Page 15

Read Sony DVP-NW50 (serv.man2) Service Manual online

15
15
3-3. Control signal input
SYSTEM 
CONTROLLER
(U1)
IR REMOTE
IR IN
(J7)
REMOTE
CONTROL
RECEIVER
(U1)
IR REMOTE
IR OUT
(J8)
PHYSICAL
LAYER
TRANSCEIVER
(U26)
NAND (U2),
TIMER (U25)
IR REMOTE
IR OUT
(J8)
TX signals
RX signals
TX+/TX-
RX+/RX-
KEY SW (S1-S23),
DECODER (U11)
Please refer to Block diagram on page 25 in the Service manual.
When SYSTEM CONTROLLER (U1) boots up, SYSTEM CONTROLLER starts to check 
control inputs of four sources in DVP-NW50.
1.  Key SW input on the set 
DECODER (U11) converts the key input detection signal and output to SYSTEM 
CONTROLLER (U1).
2. Wired IR REMOTE input
The input signal is wired SIRCS signal. The IR input signal is transferred to IR OUT terminal for 
next device automatically.
3. Remote commander input with Infrared signal
REMOTE CONTROL RECEIVER (U1) convert the Infrared signal to electrical signal.
4. Ethernet line input
The Ethernet line input is received and processed physically by PHYSICAL LAYER 
TRANSCEIVER (U26). Then, the signal is transferred to SYSTEM CONTROL (U1) and 
decoded logically.
While communicating with Ethernet line, one blue LED(D21) continue flashing by data 
communication and two red LEDs are lit continuously.
Page of 46
Display

Click on the first or last page to see other DVP-NW50 (serv.man2) service manuals if exist.