11
11
2-2. Voltage for Standby mode
14V
+12V REG
(U103)
+9V REG
(U20)
+5V REG
(U14)
+3.3V REG
(U101)
+1.25V REG
(U102)
29.5V
VCC30V-R
VCC30V-L for Digital amplifier
VCC30V-L for Digital amplifier
VCC12V for Digital amplifier
VCC 9V for Tuner
VCC 5V for LED, IR OUT
CDVCC 5V for
I2TO5VCC for RESET
, MIC, IR IN
3.3V (DVDD) for DSP
VCC 3.3V for Digital amplifier
+1.8V REG
(U13)
RVDD(3.3V) for SYSTEM CONTROLLER
CDVCC3V3 for MPEG, FLASH MEMORY
CVDD for SYSTEM CONTROLLER
1.25V(CVCC) for DSP
When AC-NW50 is connected with DVP-NW50, DC14V is supplied to DVP-
NW50.
NW50.
Then, +3.3V REG (U101) and +1.8V REG (U13) starts to supply the operation
voltage of System controller (U1).
voltage of System controller (U1).
(See on page 25 in service manual.)
+5V REG (U14) outputs I2TO5VCC to RESET (U10).
Then, RESET (U10) outputs reset signal to SYSTEM CONTROLLER (U1).
By input of this reset signal, SYSTEM CONTROLLER (U1) boots up.
When System controller (U1) boots up, red LED is lit by 98 pin of U1.