DVP-NW50 (serv.man2) - Sony DVD Service Manual (repair manual). Page 14

Read Sony DVP-NW50 (serv.man2) Service Manual online

14
14
3-2. Booting of SYSTEM CONTROLLER
SYSTEM 
CONTROLLER
(U1)
FLASH MEMORY
(U4)
SDRAM
(U3)
Green LED
(D17)
Red LED
(D16)
Please refer to Block diagram on page 25 in the Service manual.
There are two LED (D16, D17) by SYSTEM CONTROLLER. 
When SYSTEM CONTROLLER is booting, red LED is lit a moment. 
When SYSTEM CONTROLLER starts to operate correctly, blue LED is lit.
In normal operation, red LED is lit a moment only when you turns on the set. 
Next, blue LED is lit continuously.
You can confirm SYSTEM CONTROLLER operation by these LED.
If blue and red LEDs are lit continuously, please check the soldering or pattern of 
data communication line between SYSTEM CONTROLLER (U1) and FLASH
MEMORY (U4) well. 
You can confirm SYSTEM CONTROLLER operation by FL display, too.
It takes more than 30 seconds to show the clock time on FL display after 
supplying the power from AC-NW50.
As the operating system is similar to Personal Computer, the waiting time is also 
long as same as PC.
Please wait until you can see a character on FL display.
Page of 46
Display

Click on the first or last page to see other DVP-NW50 (serv.man2) service manuals if exist.