7-3
DVP-NS611HP/NS710H/NS710HP/NS717HP/NS718H/NS718HP/NS728H/NS728HP
A
1.0 ±0.08 Vp-p 
5.
Checking RGB Output R (RGB Mode)
(Europe Model)
<Purpose>
This checks RGB video output R level. If it is incorrect, correct colors
will not be displayed when connected to, for instance, projector.
Mode
HLX-504 play back
Signal
Color bars
Test point
Red Out, (15p) (75 
Ω terminated)
Instrument
Oscilloscope
Specification
A = 700 ± 70 mVp-p
Checking method:
(1)
In the Video Signal menu “1” Color Bar 100% play back.
(2)
Confirm that the R level is A.
Fig. 7-5.
6.
Checking Component Video Output Y
<Purpose>
This checks component video output Y. If it is incorrect, correct
brightness will not be attained when connected to, for instance,
projector.
Mode
HLX-504 play back
Signal
Color bars
Test point
COMPONENT VIDEO OUT (Y)
connector, (75 
Ω terminated)
Instrument
Oscilloscope
Specification
1.0 ± 0.08 Vp-p
Checking method:
(1)
In the Video Signal menu “1” Color Bar 100% play back.
(2)
Confirm that the Y level is 1.0 ± 0.08 Vp-p.
Fig. 7-6.
7.
Checking Component Video Output B-Y
<Purpose>
This checks component video output B-Y. If it is incorrect, correct
colors will not be displayed when connected to, for instance,
projector.
Mode
HLX-504 play back
Signal
Color bars
Test point
COMPONENT VIDEO OUT (P
B
)
connector (75 
Ω terminated)
Instrument
Oscilloscope
Specification
A = 700 ± 70 mVp-p
Checking method:
(1)
In the Video Signal menu “1” Color Bar 100% play back.
(2)
Confirm that the B-Y level is A.
Fig. 7-7.
8.
Checking Component Video Output R-Y
<Purpose>
This checks component video output R-Y. If it is incorrect, correct
colors will not be displayed when connected to, for instance,
projector.
Mode
HLX-504 play back
Signal
Color bars
Test point
COMPONENT VIDEO OUT (P
R
)
connector (75 
Ω terminated)
Instrument
Oscilloscope
Specification
B = 700 ± 70 mVp-p
Checking method:
(1)
In the Video Signal menu “1” Color Bar 100% play back.
(2)
Confirm that the R-Y level is B.
Fig. 7-8.