DVP-NS611HP, DVP-NS710H, DVP-NS710HP, DVP-NS717HP, DVP-NS718H, DVP-NS718HP, DVP-NS728H, DVP-NS728HP - Sony DVD Service Manual (repair manual). Page 67

Read Sony DVP-NS611HP / DVP-NS710H / DVP-NS710HP / DVP-NS717HP / DVP-NS718H / DVP-NS718HP / DVP-NS728H / DVP-NS728HP Service Manual online

7-4
DVP-NS611HP/NS710H/NS710HP/NS717HP/NS718H/NS718HP/NS728H/NS728HP
7-3. ADJUSTMENT OF VIDEO SYSTEM
Non-Euro Model
(DVP-NS611HP/NS710H/NS710HP/
NS717HP/NS718HP/NS728HP/)
NS718:CND,AUS
NS728H:AUS
1.
Checking Video  Level
<Purpose>
Checking Video Level the NTSC/PAL standard, and if not correct,
the brightness will be too large or small.
Mode
HLX-504 play back
Signal
Color bars 100%
Test point
LINE OUT (VIDEO) connector
(75 
Ω terminated)
Instrument
Oscilloscope
Specification
1.0 ± 0.08 Vp-p/ 75 
Ω termination
Adjusting method:
(1)
In the Video Signal menu “1” Color Bar 100% play back.
(2)
Confirm that the Video Level is 1.0 ± 0.08 Vp-p.
Fig. 7-9.
2.
Checking Component Video Output  Y
<Purpose>
This checks component video output Y. If it is incorrect, correct
brightness will not be attained when connected to, for instance,
projector.
Mode
HLX-504 play back
Signal
Color bars
Test point
COMPONENT VIDEO OUT (Y)
connector, (75 
Ω terminated)
Instrument
Oscilloscope
Specification
1.0 ± 0.08 Vp-p/ 75 
Ω termination
Checking method:
(1)
In the Video Signal menu “1” Color Bar 100% play back.
(2) Confirm that the Y level is 1.0 ± 0.08 Vp-p.
Fig. 7-10.
1.0 ± 0.08 Vp-p/ 
75     termination
1.0 ± 0.08 Vp-p/ 
75     termination
3.
Checking Component Video Output B-Y
<Purpose>
This checks component video output B-Y. If it is incorrect, correct
colors will not be displayed when connected to, for instance,
projector.
Mode
HLX-504 play back
Signal
Color bars
Test point
COMPONENT VIDEO OUT (P
B
)
connector (75 
Ω terminated)
Instrument
Oscilloscope
Specification
B = 700 ± 70mVp-p/ 75 
Ω termination
Checking method:
(1)
In the Video Signal menu “1” Color Bar 100% play back.
(2)
Confirm that the B-Y level is B.
Fig. 7-11.
4.
Checking Component Video Output R-Y
<Purpose>
This checks component video output R-Y. If it is incorrect, correct
colors will not be displayed when connected to, for instance,
projector.
Mode
HLX-504 play back
Signal
Color bars
Test point
COMPONENT VIDEO OUT (P
R
)
connector (75 
Ω terminated)
Instrument
Oscilloscope
Specification
B = 700 ± 70 mVp-p/ 75 
Ω termination
Checking method:
(1)
In the Video Signal menu “1” Color Bar 100% play back.
(2)
Confirm that the R-Y level is B.
Fig. 7-12.
B
B
7-4E
Page of 82
Display

Click on the first or last page to see other DVP-NS611HP / DVP-NS710H / DVP-NS710HP / DVP-NS717HP / DVP-NS718H / DVP-NS718HP / DVP-NS728H / DVP-NS728HP service manuals if exist.