SAL70200G2 - Sony Digital Camera Service Manual (repair manual). Page 38

Read Sony SAL70200G2 Service Manual online

5-4
SAL70200G2 (2.8/70-200 G SSM Ⅱ) (70-200mm F2.8 G SSM II)
4)  Click the Calculate button to measure the image.
5)  After measuring, check the  G  values.
 Average 
G  value of the three images shoot with master lens: 
(a)
 Average 
G  value of the three images shoot with checking lens:  (b)
 
Calculate button
Check the “G” value
 Fig. 
5-2-7
3. Checking Method
1)  Calculate aperture error using the following formula, and check that the aperture error is within the specification.
Aperture error = Average  G  value of checking lens (b) - Average  G  value of master lens (a) 
Specification:
 
Aperture error = -25 to +0 (WIDE end: 70 mm)
2)  When the aperture error is out of specification, perform  5-2-2. Aperture Diameter Adjustment .
5-2-2. Aperture  Diameter  Adjustment
Equipment
•   Adhesive bond (B-10)
•   Maximum Aperture jig
•  
Universal Wrench
•   Chip-A for Universal Wrench
•   Chip-B for Universal Wrench
•   Chip-C for Universal Wrench
1. Procedure
1)  Disassemble or assemble the lens as shown in Fig. 5-2-8.
 
(Remove the parts of forward (object side) from the aperture blade, perform in the condition the lens is seen.)
2)  Install the maximum aperture jig and open the aperture.
 
 Fig. 
5-2-8
Page of 103