5-3-1. Optical  Axis  Check
1)  Attach the checking lens to the flange back tester, and set the 1000 mm collimator.
 
1000 mm collimator
Checking lens
 Fig. 
5-3-3
2)  Set the focus ring of the checking lens to 
 (infinity) index or near 
 (infinity)  and adjust the optical axis, observing the microscope 
so that the chart can be seen in the center.
3)  Turn the focusing knob of the flange back tester until the chart image comes into focus.
 
Also check the optical axis aligns with the chart center. (Refer to Fig. 5-3-4.)
Note: 
Figure shows example. The cause depends on individual lens.
 
Optical Alignment
Best alignment
Incorrect aligned
e.g. As the focusing knob is turned, the chart may appear blurry as illustrated.
The cause depends on individual lens.
 Fig. 
5-3-4
4)  Perform Step (1) through Step (6) and ensure that the AS and CB values are within specifications. 
Note:
  If the specification is  CB  only, steps 1 to 3 are not required.
 AS 
(astigmatism)
 
The phenomenon where the flare on the ring chart appears in a cruciform shape with the ring chart in the sharpest focus. (Fig. 5-3-5 (a))
(1)  Turn the focusing knob until the flare becomes minimum between two approximately opposite points on the ring chart edge (as 
shown with the arrows in Fig. 5-3-5 (b)), and then read the dial gauge value. <A>
(2)  Turn the focusing knob until the flare becomes minimum between two points with the phase of the flare rotated by 90 degrees 
from the above condition (as shown with two arrows in Fig. 5-3-5 (c)), and then read the dial gauge value. <B>
(3)  Calculate the AS value (absolute difference between <A> and <B>) and ensure that it is within specifications.
 
AS value = <A> - <B>
 
CB (Center Blur)
 
The phenomenon where the flare on the ring chart trails in one direction with the ring chart in the sharpest focus. (Fig. 5-3-5 (d))
(4)  Turn the focusing knob until the ring chart edge in the direction of the maximum flare is in the sharpest focus (as shown with 
the arrow in Fig. 5-3-5 (e)), and then read the dial gauge value. <C>
(5)  Turn the focusing knob until the ring chart edge, opposite 180 degrees from the above condition (as shown with the arrow in Fig. 
5-3-5 (f)) is in focus, and then read the dial gauge value. <D>
(6)  Calculate the CB value (absolute difference between <C> and <D>) and ensure that it is within specifications.
 
CB value = <C> - <D>
 
(1)
(1)
(2)
(2)
(5)
(4)
AS
E
D
F
H
G
I
CB
 Fig. 
5-3-5
Specification:
WIDE end
TELE end
CB
Less than 0.07 mm
Less than 0.1 mm
AS
Less than 0.07 mm
Less than 0.07 mm
 Table 
5-3-1
5)  If the specifications of CB and AS are not satisfied, perform the  5-3-2. Optical Axis Adjustment .
6)  When their values meet the specification, perform  5-5. FOCUS-SHIFT/FLANGE BACK (f F) CHECK/ADJUSTMENT .
5-3-2. Optical Axis Adjustment
1)  Push the 1 group ball frame tube block to reduce the gap or play.
a.  While observing the collimator, confirm the direction where the CB occurs.
b.  Push the 1 group ball frame tube block in the direction of CB.
c.  Observe the collimator again and confirm the optical axis.
 
G1 Holding Rubber
1 Group Ball Frame Tube Block
G1 Holder Ring
 Fig. 
5-3-6