Adhesive bond (B-10): J-6082-612-A
1.
Overlay the aperture blade unit clockwise.
2.
Open the aperture operate plate unit and install the aperture hold ring so that the aperture blade unit protrudes a little from the hole.
3.
Install nine screws tentatively.
4.
After performing [5-2-2. Aperture Diameter Adjustment], tighten firmly nine screws and apply the adhesive bond (B-10) as shown
below.
5.
Apply the adhesive bond (B-10) to the portion A (head of screw) at three locations (at an interval of every two screws).
6.
Apply the adhesive bond (B-10) portion B (protruded portion at the tip of screw) (9 locations).
Apply the adhesive bond (B-10)
Portion A (head of screw) (3 locations)
(at an interval of every two screws)
Apply the adhesive bond (B-10)
Portion B (protraded at the tip of screw)
(9 locations)
Overlay the aperture 
blade unit clockwise
Install the aperture hold ring.
(The aparture blade unit 
protrudes a little from the hole)
Set the aperture operate
plate unit to the open state
Aperture Hold Ring
Screw
(9 pieces)