Attach the apreture blade, aligning the boss of apreture blade with the boss hole of apreture operating plate.
Note:
At this moment, the preset lever of apreture operating plate should be in the cut portion of aperture blade holding ring.
HELP40
Anti-diffusion agent (A-20): J-6082-611-A
1.
Apply the anti-diffusion (A-20) to the indicated portion of aperture blade holding ring.
2.
Attach the aperture blade, aligning its boss with the boss hole of aperture blade holding ring. At this moment, overlay the aperture
blade clockwise.
3.
Attach the last aperture blade, releasing the blade installed first in the arrow direction.
Cut Portion
Preset Lever
Aperture Operating Plate
Aperture Blade
Boss
Boss Hole
Aperture Blade Holding Ring
Aperture Blade
Boss
Boss
Boss Hole
Boss Hole
Aperture Blade
Aperture Blade Holding Ring
Aperture Blade Holding Ring
Apply the anti-diffusion (A-20)
(Entire circumference)