SAL24105 - Sony Digital Camera Service Manual (repair manual). Page 37

Read Sony SAL24105 Service Manual online

HELP
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
HELP37
Adhesive bond (B-10): J-6082-612-A
1.
Attach the aperture unit holding spring so that the opening of aperture unit holding spring does not cover the cut portion of focus cam
tube block as shown in the figure.
2.
Attach the aperture unit holding spring to the focus cam tube. After adjusting the aperture diameter, apply the adhesive bond (B-10)
to the idicated portion.
Note:
Perform aperture diameter adjustment, referring to 4-16 page.
Apply the adhesive bond (B-10)
Focus Cam Tube
Aperture Operating Plate
Aperture Blade
Aperture Blade Holding Ring
Aperture Unit Holding Spring
Cut Portion
Opening
Aperture Unit Holding
Spring