DSC-TF1 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 4

Read Sony DSC-TF1 (serv.man2) Service Manual online

DSC-TF1_ADJ
5-4
5-2. CAMERA SECTION ADJUSTMENTS
5-2-1. MS/BP Adjustment
The Iris/Mechanical Shutter/Bad Pixel Adjustment order is as follows.
Small pattern box (PTB-1450) setting:
Color temperature = 3150 ± 50K
Luminance: LV12.3 ± 0.2
Adjustment order
Screen display
The adjustment finished normally.
O Hall OK
O ADJUST IRIS OK
O Mshutter OK
O PreviewPixel OK
O Still Pixel OK
The adjustment is complete
Fig. 5-2-2
The adjustment is finished abnormally.
O Hall OK
O ADJUST IRIS OK
O Mshutter OK
X PreviewPixel NG
O Still Pixel OK
Malfunction of PreviewPixel
adjustment
Fig. 5-2-3
O Hall OK
X ADJUST IRIS NG
O Mshutter OK
O PreviewPixel OK
O Still Pixel OK
Malfunction of Iris
adjustment
Fig. 5-2-4
O Hall OK
O ADJUST IRIS OK
X Mshutter NG
O PreviewPixel OK
O Still Pixel OK
Malfunction of mechanical
shutter adjustment
Fig. 5-2-5
Set the camera to the adjustment mode.
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-2-1)
Press the control button “ v (Key Up)”, then MS/BP Adjustment starts.
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-2-3 to 5-2-17)
In this case, confirm the adjusting environment
and readjust.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
the adjustment completion indication appears
on the screen. (Fig. 5-2-2)
In case of the adjustment is finished normally,
Turn off the power to quit the adjustment mode.
The adjustment is finished abnormally.
O Hall OK
O ADJUST IRIS OK
O Mshutter OK
O PreviewPixel OK
X Still Pixel NG
Malfunction of Still Pixel
adjustment
Fig. 5-2-6
 
O Hall OK
X ADJUST IRIS NG
X Mshutter NG
O PreviewPixel OK
O Still Pixel OK
Malfunction of iris &
mechanical shutter
adjustment
Fig. 5-2-7
O Hall OK
X ADJUST IRIS NG
O Mshutter OK
X PreviewPixel NG
O Still Pixel OK
Malfunction of iris &
PreviewPixel adjustment
Fig. 5-2-8
 
O Hall OK
X ADJUST IRIS NG
O Mshutter OK
O PreviewPixel OK
X Still Pixel NG
Malfunction of iris &
Still Pixel adjustment
Fig. 5-2-9
O Hall OK
O ADJUST IRIS OK
X Mshutter NG
O PreviewPixel OK
X Still Pixel NG
Malfunction of mechanical
shutter & Still Pixel
adjustment
Fig. 5-2-10
 
O Hall OK
O ADJUST IRIS OK
X Mshutter NG
X PreviewPixel NG
O Still Pixel OK
Malfunction of 
mechanical shutter &
PreviewPixel adjustment
Fig. 5-2-11
O Hall OK
O ADJUST IRIS OK
O Mshutter OK
X PreviewPixel NG
X Still Pixel NG
Malfunction of PreviewPixel 
& Still Pixel adjustment
Fig. 5-2-12
 
O Hall OK
X ADJUST IRIS NG
X Mshutter NG
X PreviewPixel NG
O Still Pixel OK
Malfunction of iris & 
mechanical shutter &
PreviewPixel adjustment
Fig. 5-2-13
O Hall OK
X ADJUST IRIS NG
O Mshutter OK
X PreviewPixel NG
X Still Pixel NG
Malfunction of iris &
PreviewPixel &
Still Pixel adjustment
Fig. 5-2-14
 
O Hall OK
X ADJUST IRIS NG
X Mshutter NG
O PreviewPixel OK
X Still Pixel NG
Malfunction of iris &
mechanical shutter &
Still Pixel adjustment
Fig. 5-2-15
O Hall OK
O ADJUST IRIS OK
X Mshutter NG
X PreviewPixel NG
X Still Pixel NG
Malfunction of
mechanical shutter &
PreviewPixel &
Still Pixel adjustment
Fig. 5-2-16
 
X Hall NG
X ADJUST IRIS NG
X Mshutter NG
X PreviewPixel NG
X Still Pixel NG
Malfunction of
all adjustment
Fig. 5-2-17
Equipment required: Small pattern box (PTB-1450)
Small pattern box
(PTB-1450)
0.5 to 1.0 cm
Black cloth
Camera
Clear chart
Fig. 5-2-1
Page of 8