6-34
DSC-T1
6-2. SERVICE MODE
2-1.
APPLICATION FOR ADJUSTMENT (SEUS)
The application for adjustment (SEUS) is used for changing the
calculation coefficient in signal processing, EVR data, etc. The SEUS
performs bi-directional communication between the personal
computer (PC) and the unit using the USB signal. The resultant
data of this bi-directional communication is written in the non-
volatile memory.
2-1-1.
Using Method of SEUS
1. Connection
1)
Connect the HASP key to the USB port of the PC.
2)
Connect the camera to another USB port of the PC.
3)
Insert a memory stick DUO to the camera.
4)
Confirm that the camera starts in the USB mode.
5)
Start the SEUS on the PC.
6)
Click [Connect] on the SEUS screen. If the connection is
normal, the SEUS screen will be as shown in Fig. 6-2-1,
indicating the “connected” state.
Note:
The SEUS will go in “disconnect” state, if the camera is turned
off (for instance, by resetting the unit). In such a case, click
[Connect] on the SEUS screen to restore the “connected” state.
2. Operation
• Page change
To change the page, click [Page] on the SEUS screen and enter
the page to be changed. The page is displayed in hexadecimal
notation.
• Address change
To change the address, click [Address] on the SEUS screen and
enter the address to be changed. Or click [ B ] to increase the
address, click [ b ] to decrease the address. The address is
displayed in hexadecimal notation.
• Data change
To change the data, click [Set] on the SEUS screen and enter the
data. Or click [ v ] to increase the data, click [ V ] to decrease
the data. The data is displayed in hexadecimal notation.
This operation does not write the data to the nonvolatile memory.
If you want to write the changed data, click [Save] to write it.
• Data saving
To write the all changed data to the nonvolatile memory, click
[Save] on the SEUS screen. and wait for 2 sec.
• Data reading
The data displayed on the SEUS screen are the data values at the
time when the pages and addresses were set, and they are not
updated automatically. To check the data change, click [Read]
on the SEUS screen and update the displayed data.
2-1-2.
Precaution on Use of SEUS
Mishandling of the SEUS may erase the correct adjustment data at
times. To prevent this, it is recommended that all adjustment data
be saved before beginning adjustments.
1)
Click [Page Edit] on the SEUS screen.
2)
Click [Page], and enter the page number to be saved.
3)
Click [Read] to read the data to be saved from the camera.
4)
Click [File] and save the data to the PC.
Fig. 6-2-1.
Page of 40