DSC-T1 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 33

Read Sony DSC-T1 (serv.man2) Service Manual online

6-31
DSC-T1
3. VCO Adjustment (SY-95 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
PLAY ( 
 )
Subject
Arbitrary
Measurement Point
Data of page: 80, address: 02
Measuring Instrument
Adjustment Page
8F
Adjustment Address
23
Specified Value
01
Note1:
A memory stick DUO must be inserted.
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting during
LCD System Adjustments” is
performed.
2
8F
34
32
Set the data.
3
80
00
00
Set the data.
4
80
01
00
Set the data.
5
80
00
01
Set the data.
6
80
02
Read the data, and check it is “01”.
(Note2)
7
If finish the LCD system
adjustments, release the data
setting.
(See “1. Data Setting during
LCD System Adjustments”.)
Note2:
If the data is other than “01”, adjustment has errors. See the
following table.
Data of page: 80,
Contents of adjustment error
address: 02
01
Normally finished
10
Reached an upper limit
20
Reached a lower limit
30
Time out
40
Out of adjustment range
50
Adjustment is impossible
4. Bright Adjustment (SY-95 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
PLAY ( 
 )
Subject
Arbitrary
Measurement Point
Data of page: 80, address: 02
Measuring Instrument
Adjustment Page
8F
Adjustment Address
25
Specified Value
01
Note1:
A memory stick DUO must be inserted.
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting during
LCD System Adjustments” is
performed.
2
8F
38
A8
Set the data.
3
80
00
00
Set the data.
4
80
01
00
Set the data.
5
80
00
03
Set the data.
6
80
02
Read the data, and check it is “01”.
(Note2)
7
If finish the LCD system
adjustments, release the data
setting.
(See “1. Data Setting during
LCD System Adjustments”.)
Note2:
If the data is other than “01”, adjustment has errors. See the
following table.
Data of page: 80,
Contents of adjustment error
address: 02
01
Normally finished
10
Reached an upper limit
20
Reached a lower limit
30
Time out
40
Out of adjustment range
50
Adjustment is impossible
Page of 40
Display

Click on the first or last page to see other DSC-T1 (serv.man2) service manuals if exist.