DSC-R1 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 36

Read Sony DSC-R1 (serv.man4) Service Manual online

6-34
DSC-R1_ADJ
Video System Adjustment screen
Fig. 6-1-86
Camera System Adjustment screen
Fig. 6-1-87
LCD System Adjustment screen
Fig. 6-1-88
EVF System Adjustment screen
Fig. 6-1-89
5.
Data Save Error
Fig. 6-1-85
Symptom
data cannot be saved normally. (The data set-
ting during adjustment cannot be cancelled)
Cause
Data writing to the flash memory failed.
Connection is faulty.
Power supply is not installed correctly.
Remedy
On the SEUS Operation screen, 
[Set]
 the data
to the pages and addresses displayed in the
message, and 
[Save]
  them. (Cancel manu-
ally the data setting during adjustment.)
Check the connection.
Install the power supply correctly.
1-7-2.
Precautions When an Error Occurred
The Automatic Adjustment Program sets the data for adjustment
before the adjustment starts. Accordingly, if the adjustment termi-
nates by an error, the data during the adjustment may be left in the
camera.
Note 1:
With this data left in the camera, the camera will not
operate normally.
In this case, the 
[Release Data Setting]
  button is displayed in
“red” on the screen as shown in Fig. 6-1-86 to Fig. 6-1-89. Click
the 
[Release Data Setting]
 button to cancel the data setting. When
the data setting is cancelled, the button color becomes “white”.
Note 2:
When “Data Save Error” occurred,  the 
[Release Data
Setting]
 button is displayed in “white”.
To cancel the data setting, perform it on the SEUS Op-
eration screen. How to cancel the data setting is displayed
in the error message.
How to cancel the 
data setting during 
adjustment is 
display here.
Page of 43
Display