DSC-R1 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 31

Read Sony DSC-R1 (serv.man4) Service Manual online

6-29
DSC-R1_ADJ
11. CAMERA Adjustment 8
Note:
To detect a high temperature defect in the CAMERA Ad-
justment 8, the camera must be aged for more than 30 min-
utes at the temperature 40
°
C to 45
°
C. The detection of a
defect will fail unless the aging is performed in the envi-
ronment of exact temperature kept in a range of 40
°
C to
45
°
C.
[Aging method]
1) Click the [Before Aging] button in the CAMERA Adjustment 1.
2) Automatic adjustment program sets the timer to 30 minutes in
the camera.
3) Upon successful completion of setting, the following message
is displayed. Click the [OK] button.
Fig. 6-1-69
4) Disconnect the USB cable from the PC, and then disconnect
the power cord from the AC adaptor. (POWER OFF)
5) Put the camera in the environment of temperature 40
°
C to 45
°
C,
and connect the power cord to the AC adaptor. (POWER ON)
(For the aging environment, see 
“4. Preparation of Aging En-
vironment”
 (page 6-8).)
6) In about 3 seconds after the power was turned on, the LCD
screen color will become red and the 30-minute timer will start.
7) After 30 minutes elapsed, the LCD screen color will change
from red to black, indicating the completion of aging.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. C MOS High Temp. Dark & FD Def.
3. Three Continuos Def. Check
4. C MOS Blinking Def.
5. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Connect the USB cable to the PC.
2) Click the [Start]  button in the CAMERA Adjustment 8, and
the following message will be displayed. If the aging has com-
pleted, click the [OK] button. Or, if the aging is not performed,
click the [Cancel] button to interrupt the adjustment.
Fig. 6-1-70
3) Click the [OK] button to execute the items from “1. Data Set-
ting during Camera Adj.” to “5. Release of Data Setting dur-
ing Camera Adj.”.
4) Upon successful completion of all items in the CAMERA Ad-
justment 8, the following message is displayed. Click the [OK]
button.
Fig. 6-1-71
Page of 43
Display