DSC-R1_ADJ
1-8.
INITIALIZATION OF DATA
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note:
If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “16”.
4) Click 
[All]
  of the ALL SELECT buttons to select all pages.
(Fig. 6-1-90 A)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Select page: 40, address: 38 and set data: 00.
9) Select page: 2F, address: 92 and set data: 1D.
10) Select page: 2F, address: A2 and set data: 1D.
11) Select page: BC, address: 89 and set data: 03.
12) Select page: 8E, address: 00 and set data: 20.
13) Click 
[Save]
 on the SEUS screen.
14) Select page: 80, address: 34, and check that the data is “00”.
15) Select page: 80, address: 30, and check that the data is “00”.
16) Perform “VIDEO OUT Default Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
20
00
29 
[Set]
2
20
01
29 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click 
[Con-
nect]
 on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the
power button.)
Fig. 6-1-90
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1:
If the 6B or 6D or 6E or 6F or 78 page data have been
initialized, the following adjustment needs to be per-
formed again.
1) Camera system adjustments
Note 2:
If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
3) EVF system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “16”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-90
B
)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Select page: 40, address: 38 and set data: 00.
9) When 2F page is initialized, select page: 2F, address: 92 and
set data: 1D.
10) When 2F page is initialized, select page: 2F, address: A2 and
set data: 1D.
11) When BC page is initialized, select page: BC, address: 89 and
set data: 03.
12) When 8E page is initialized, select page: 8E, address: 00 and
set data: 20.
13) Click 
[Save]
 on the SEUS screen.
14) Select page: 80, address: 34, and check that the data is “00”.
15) Select page: 80, address: 30, and check that the data is “00”.
16) When 4F page is initialized, perform “VIDEO OUT Default
Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
20
00
29 
[Set]
2
20
01
29 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click 
[Con-
nect]
 on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the
power button.)
B
A
16
Ver 1.2 2005.11
Page of 43
Display