1-4-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
1
3
0
1
The internal memory has experienced a
media error.
media error.
Turn the power off and on again.
The internal memory has experienced a
format error.
format error.
Format the internal memory.
Memory card is unformatted.
Format the memory card.
Memory card is broken.
Insert a new memory card.
Memory card type error
Insert a supported memory card.
The camera cannot read or write data on
the memory card.
the memory card.
Turn the power off and on again, or taking out and inserting the
memory card several times.
memory card several times.
C
3
2
0
1
Trouble with hardware
Turn the power off and on again.
E
6
1
0
0
Difficult to adjust focus
(Cannot initialize focus)
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not
recover, check the focus reset sensor of lens block (pin 6 of
CN401 on the SY-254 board). If it is OK, check the focus motor
drive IC (IC401 on the SY-254 board).
recover, check the focus reset sensor of lens block (pin 6 of
CN401 on the SY-254 board). If it is OK, check the focus motor
drive IC (IC401 on the SY-254 board).
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
(Cannot initialize zoom lens.)
Retry turn the power on by the power switch. Check the zoom
reset sensor of lens block (pin 0 of CN401 on the SY-254
board) when zooming is performed when the zoom button is
operated. If it is OK, check the zoom motor drive IC (IC401
on the SY-254 board).
reset sensor of lens block (pin 0 of CN401 on the SY-254
board) when zooming is performed when the zoom button is
operated. If it is OK, check the zoom motor drive IC (IC401
on the SY-254 board).
E
6
2
0
2
Abnormality of IC for steadyshot.
Check or replacement of the IC for steadyshot (IC401 on the
SY-254 board).
SY-254 board).
E
6
2
1
0
Lens initializing failure.
Check or replacement of the IC for steadyshot (IC401 on the
SY-254 board).
SY-254 board).
E
6
2
1
1
Lens overheating (PITCH).
Check the HALL element (PITCH) of optical image stabilizer
(pin rk, t; of CN401 on the SY-254 board). If it is OK, check
PITCH angular velocity sensor (SE401 on the SY-254 board)
peripheral circuits.
(pin rk, t; of CN401 on the SY-254 board). If it is OK, check
PITCH angular velocity sensor (SE401 on the SY-254 board)
peripheral circuits.
E
6
2
1
2
Lens overheating (YAW).
Check the HALL element (YAW) of optical image stabilizer
(pin ef, eh of CN401 on the SY-254 board). If it is OK, check
YAW angular velocity sensor (SE401 on the SY-254 board)
peripheral circuits.
(pin ef, eh of CN401 on the SY-254 board). If it is OK, check
YAW angular velocity sensor (SE401 on the SY-254 board)
peripheral circuits.
E
6
2
2
0
Abnormality of thermistor.
Check the OIS temp sensor of optical image stabilizer (pin qs
of CN401 on the SY-254 board).
of CN401 on the SY-254 board).
E
9
1
0
1
Abnormality when flash is being charged. Checking of flash unit or replacement of flash unit. (Note)
E
9
2
0
0
Non-standard battery is used.
Use the compatible battery only.
E
9
4
0
0
Internal memory fault
Inspect the internal memory (IC801 on the SY-254 board).
E
9
5
0
0
GPS hardware error
Check whether the coaxial cable of connected between AT-
039 board and RL-098 or RL-099 flexible board of connected
between SY-254 board and RL-098 board is broken, and check
whether it is inserted imperfectly. If there is no problem the
coaxial cable or flexible board, inspect or replacement of the
AT-039 or RL-098 board..
039 board and RL-098 or RL-099 flexible board of connected
between SY-254 board and RL-098 board is broken, and check
whether it is inserted imperfectly. If there is no problem the
coaxial cable or flexible board, inspect or replacement of the
AT-039 or RL-098 board..
Note: After repair, be sure to perform “1-5. PROCESS AFTER FIXING FLASH ERROR”.
1-5. PROCESS AFTER FIXING FLASH ERROR
When “FLASH error” (Self-diagnosis Code E : 91 : 01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash
is changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Flash error code can be initialized by the operations on the HOME screen.
is changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Flash error code can be initialized by the operations on the HOME screen.
Method for Initializing the Flash Error Code
Initialize
Initializes the setting to the default setting.
Even if you execute this function, the images are retained.
Even if you execute this function, the images are retained.
1 MENU t
(Settings)
t (Main Settings) t [Initialize] t [OK] t
z on the control button
• Be sure not to turn off the camera while initializing.
Note
1-6. GPS RECEIVING CHECK (HX5V)
After a part of set was replaced or after the set was assembled, check the reception of GPS signal.
Click on the first or last page to see other DSC-HX5 / DSC-HX5C / DSC-HX5V (serv.man2) service manuals if exist.