AMOUNT_LENS - Sony Digital Camera Service Manual (repair manual). Page 12

Read Sony AMOUNT_LENS Service Manual online

– 12 –
LENS GENERAL ADJUSTMENT GUIDE
1-2-2. Connection of Finished Inspection JIG II and Startup of Lens
Adjustment Program (ActuatorCheckerSAM)
Note 1:
Confirm that “1-1-2. Installation of ActuatorCheckerSAM (For Using Finished Inspection JIG II (J-6082-710-A))” has been
completed before this procedure is executed.
Note 2:
In case of performing Finished inspection, be sure to perform in the condition that the lens is laid down (do not perform in the
lens standing condition).
Equipment
• Personal Computer
• Finished Inspection JIG II (AC 100 - 240 V) (J-6082-710-A)
Note: The cables and so on are not supplied as accessories.
• AC Cable (Sold on the Market)
• RS232C Cable (D-Sub 9 Pins (Male with Securing Screws) 
,
 D-Sub 9 Pins (Female with Securing Screws)) Straight Type (Sold on
the Market)
• USB to Serial Cable (D-Sub 9 Pins (Male)) (Sold on the Market)
• M-BOX-JIG (J-6082-722-A) (Or the Jig supplied with Finished Inspection JIG)
• Lens Adjustment Program (ActuatorCheckerSAM)
1. Connection
Connect equipment and checking lens as shown in Fig.1-2-3.
Note:
ActuatorCheckerSAM cannot start up without the connection to the finished inspection JIG II.
Fig.1-2-5
2. Startup of Lens Adjustment Program (ActuatorCheckerSAM)
1)
Turn on the personal computer and the finished inspection JIG II.
2)
Start up “ActuatorCheckerSAM” from an arbitrary folder.
Note:
At the first time using, the followings appear on the screen (Fig. 1-2-6).
It is required to ask HQ about the password for the Com/User Characteristic No. and the manufacturer/type name of the personal
computer.
Ex. Com/User Characteristic No.: iYdDZfq9q
Personal Computer: SONY PCV-RZ33P
It is no need to input password to the computer once registered.
(The screen requires password doesn’t appear.)
If the personal computer or the finished inspection JIG II is changed, the password and the Com/User Characteristic No. are changed.
Therefore on the startup, the password input is required again.
3)
Input the password and click “OK[Ent]”, the following appears on the screen (Fig. 1-2-7).
Fig.1-2-6
Fig.1-2-7 (Ex.: SAL1855)
Finished Inspection JIG II
AC Cable
D-sub 9 Pins: Male
D-sub 9 Pins: Female
RS232C Cable
USB to Serial Cable
Lens
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2009.05
Page of 81