– 8 –
LENS GENERAL ADJUSTMENT GUIDE
4. Setting procedure using the half completion inspection JIG
After confirming the PC card setting, continue the steps.
1)
Connect the USB cable (white) leading from the half-finished inspection JIG to the PC.
2)
It can be automatically used.
3)
Start up [InstaCal]. (See page 7.)
4)
The menu below appears. Confirm that “USB-1208**” is checked and then click [OK].
Note:
“**” may change.
Fig.1-1-17
5)
When the menu below appears, confirm that “PC-CARD-DI048” is displayed in “Board#0” and “USB-1208**” is displayed in
“Board#1”.
Note:
If they are reversed, the adjustment program does not start up.
Fig.1-1-18
6)
Click “Board#1” to highlight it blue. Then, click the set button at third position from left on the top row.
Fig.1-1-19