Read Sony WX-800UI Service Manual online
WX-800UI
6
2. Confi rmation After Destination Setting
Execute the following operation after completing the destination
setting, and confi rm a correct destination was set.
Execute the following operation after completing the destination
setting, and confi rm a correct destination was set.
Destination setting checking method:
1. In the state of source off (the clock is displayed on the liquid
1. In the state of source off (the clock is displayed on the liquid
crystal display), enter the test mode by pressing the buttons
in order of the [ 4] t [5] t [PAUSE 6] (press only the
in order of the [ 4] t [5] t [PAUSE 6] (press only the
[PAUSE 6] button for two seconds).
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
Clock display
2. In the state in which the system controller version is displayed
on the liquid crystal display (refer to following fi gure), enter
the destination setting value display mode by pressing the
[DSPL SCRL ] button twice.
the destination setting value display mode by pressing the
[DSPL SCRL ] button twice.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
System controller version
3. Confi rm the alphanumeric character of 12 digits of in liquid
crystal display is an value correctly input.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
Destination code
12 digits
OP0
OP1
OP2
OP3
OP4
OP5
4. The resetting operation is executed by pressing the [SOURCE
OFF] button for 1 second after the confi rming ends, and the
unit returns to the normal condition.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
Display after reset
MODEL IDENTIFICATION
Distinguish by Part No. on the bottom side of the main unit.
Distinguish by Part No. on the bottom side of the main unit.
Part No.
Part No.
Model Number Label
– Bottom view –
(AEP, Russian and UK models)
(AEP, Russian and UK models)
– Bottom view –
(E, Indian and Australian models)
(E, Indian and Australian models)
Model Number Label
Part No.
Model
4-575-524-0[]
AEP and UK models (EUR)
4-575-525-0[]
Russian model (RU2)
4-575-526-0[]
E and Australian models (E)
4-575-527-0[]
Indian model (IN)
TEST DISCS
Use following TEST DISC (for CD) when this unit confi rms the
operation and checks it.
Use following TEST DISC (for CD) when this unit confi rms the
operation and checks it.
Part No.
Description
3-702-101-01 DISC
(YEDS-18),
TEST
4-225-203-01 DISC
(PATD-012),
TEST
NOTE OF PERFORMING THE OPERATION CHECK
When performing the operation check in the state that is removed
the CD mechanism deck from the main unit, it is necessary to use
a long fl exible fl at cable.
When performing the operation check, use following fl exible fl at
cable.
When performing the operation check in the state that is removed
the CD mechanism deck from the main unit, it is necessary to use
a long fl exible fl at cable.
When performing the operation check, use following fl exible fl at
cable.
Part No.
Description
1-846-819-31
CABLE FLEXIBLE FLAT (27 CORE)
(Length: 150 mm)