Read Sony CDX-V60 Service Manual online
– 16 –
+
–
–
+
–
–
digital voltmeter
DC power supply
TP
(EHS)
TP
(VREF)
TP
(GND)
RV601
adjustment screw
servo board
retainer plate
bend
slider
mechanism deck rear view
5-2.
LINEAR POSITION SENSOR ADJUSTMENT
Notes:
1. When the elevator height is adjusted as part of any repairs, the
linear position sensor (RV601) must be adjusted.
This adjustment is for absorbing the variation in the perfor-
mance of the RV601 parts and is not a mechanical deck
adjustment.Therefore, this adjustment is only carried out when
the mechanical deck elevator height adjustment (Address 1
adjustment) is made.
This adjustment is for absorbing the variation in the perfor-
mance of the RV601 parts and is not a mechanical deck
adjustment.Therefore, this adjustment is only carried out when
the mechanical deck elevator height adjustment (Address 1
adjustment) is made.
2. Never supply power to the set main unit during this
adjustment.(Have the bus cable disconnected.)
Connection:
Adjustment method:
1. Extend the plate holding down the RV601 slider with radial
1. Extend the plate holding down the RV601 slider with radial
pliers to free the slider.
2. Connect the TP (VREF) on the servo board to a dc power sup-
ply.
3. Connect the TP (EHS) on the servo board to a digital voltme-
ter.
4. Supply 5.00 ± 0.01 V power from the dc power supply to the
TP (VREF).
5. Turn the adjustment screw so that the digital voltmeter reads
4.03 ± 0.02 V.
6. After the adjustment,disconnect the dc power supply and the
digital voltmeter.
7. Apply the power supply to the set main unit, insert the maga-
zine, operate, and check that there is no address deviation.
8. Bend the retainer plate back the way it was originally.
9. Apply suitable locking compound to the adjustment screw.
9. Apply suitable locking compound to the adjustment screw.
* After adjusting the linear position sensor (RV601) , put in
the magazine and operate. If address deviation is found, re-
check the elevator height adjustment (Elevator Address 1 ad-
justment).
The following causes are possible.
Examples:
• The mechanical deck gear (TDFP) and magazine gear teeth
check the elevator height adjustment (Elevator Address 1 ad-
justment).
The following causes are possible.
Examples:
• The mechanical deck gear (TDFP) and magazine gear teeth
are not meshing.
• During ejection, the gear (EL1) was not in the prescribed
position.
• After magazine ejection was carried out five times, the
magazine lock was unlocked.
[SERVO BOARD] (Conductor Side)
Click on the first or last page to see other CDX-V60 service manuals if exist.