6. CHECK PRIOR TO REPAIRS
These checks are performed before replacing parts according to
“approximate specifications” to determine the faulty locations. For
details, refer to “Checks Prior to Parts Replacement and Adjust-
ments”(See page 4).
These checks are performed before replacing parts according to
“approximate specifications” to determine the faulty locations. For
details, refer to “Checks Prior to Parts Replacement and Adjust-
ments”(See page 4).
6-1. Laser Power Check
Connection:
Checking Procedure:
1. Set the laser power meter on the objective lens of the optical
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the m but-ton
or M button to move the optical pick-up)
Connect the digital voltmeter to TPO 502 (I+3 V) and TP503 (IOP)
on the MD board.
Connect the digital voltmeter to TPO 502 (I+3 V) and TP503 (IOP)
on the MD board.
2. Turm the JOG dial to display “LDPWR CHECK”.
3. Press the YES/ENTER button once to display “LD 0.9 mW $
3. Press the YES/ENTER button once to display “LD 0.9 mW $
”. Check that the reading of the laser power meter become
0.80 to 0.96 mW.
4. Press the YES/ENTER button once more to display “LD 7.0
mW $
”. Check that the reading the laser power meter and
digital voltmeter satisfy the specified value.
Specified Value:
Laser power meter reading : 6.8 - 7.2 mW
Digital voltmeter reading : Value on the optical pick-up label
Laser power meter reading : 6.8 - 7.2 mW
Digital voltmeter reading : Value on the optical pick-up label
±
10 %
5. Press the NO/CANCEL button to display “LDPWR CHECK”
and stop the laser emission.
(The NO/CANCEL button is effective at all times to stop the
laser emission)
(The NO/CANCEL button is effective at all times to stop the
laser emission)
Note 1
: After step 4, each time the YES/ENTER button is pressed,
the display will be switched “LD 0.7 mW $ ”,
“LD 6.2 mW $
“LD 6.2 mW $
”,
and “LD WP
$ ”. Nothing needs to be performed
here.(
= correction)
6-2. Focus Bias Check
Change the focus bias and check the focus tolerance amount.
Checking Procedure:
1. Load the test disc (MDW-74/AU-1).
2. Turn the JOG dial to display “CPLAY MODE”.
3. Press the YES/ENTER button twice to display “CPLAY MID”.
4. Press the NO/CANCEL button when “C1 =
Change the focus bias and check the focus tolerance amount.
Checking Procedure:
1. Load the test disc (MDW-74/AU-1).
2. Turn the JOG dial to display “CPLAY MODE”.
3. Press the YES/ENTER button twice to display “CPLAY MID”.
4. Press the NO/CANCEL button when “C1 =
AD =
”
is displayed.
5. Turn the JOG dial to display “FBIAS CHECK”.
6. Press the YES/ENTER button to display “
6. Press the YES/ENTER button to display “
/
c =
”.
The first four digits indicate the C1 error rate, the two digits
after (( / )) indicate ADER, and the 2 digits after “c =” indicate
the focus bias value.
Check that the C1 error is below 50 and ADER is below 2.
after (( / )) indicate ADER, and the 2 digits after “c =” indicate
the focus bias value.
Check that the C1 error is below 50 and ADER is below 2.
7. Press the YES/ENTER button to display “
/
b =
”.
Check that the C1 error is about 200 and ADER is below 2.
8. Press the YES/ENTER button to display “
/
a =
”.
Check that the C1 error is about 200 and ADER is below 2.
9. Press the NO/CANCEL button, then press the Z (MD)
button and take out the test disc.
6-3. C PLAY Check
MO Error Rate Check
Checking Procedure:
1. Load the test disc (MDW-74/AU-1).
2. Turn the JOG dial to display “CPLAY MODE”.
3. Press the YES/ENTER button to display “CPLAY MID”.
4. The display changes to “C1 =
Checking Procedure:
1. Load the test disc (MDW-74/AU-1).
2. Turn the JOG dial to display “CPLAY MODE”.
3. Press the YES/ENTER button to display “CPLAY MID”.
4. The display changes to “C1 =
AD =
”.
5. If the C1 error rate is below 80, check that ADER is below 2.
6. Press the NO/CANCEL button to stop playback, then press
6. Press the NO/CANCEL button to stop playback, then press
the Z (MD) button and take out the test disc.
CD Error Rate Check
Checking Procedure:
1. Load the check disc (MD) TDYS-1.
2. Turn the JOG dial to display “CPLAY MODE”.
3. Press the YES/ENTER button twice to display “CPLAY MID”.
4. The display changes to “C1 =
1. Load the check disc (MD) TDYS-1.
2. Turn the JOG dial to display “CPLAY MODE”.
3. Press the YES/ENTER button twice to display “CPLAY MID”.
4. The display changes to “C1 =
AD =
”.
5. Check that the C1 error rate is below 50.
6. Press the NO/CANCEL button to stop playback, then press
6. Press the NO/CANCEL button to stop playback, then press
the Z (MD) button and take out the check disc.
laser
power meter
power meter
Optical pick-up
objective lens
objective lens
R622
C508
C521
C512
L503
C502
R511
C518
C511
C505
R505
R510
Q503
R508
R513
R509
R517
C519
C517
C520 C522
R519
R516
R512
C506
R504
R503
Q506
Q507
Q505
Q504
R518
Q502
R515
IC502
R5
2
L501
L506
C611
R633
Q501
R514
R502
C607
TP503
(IOP)
TP502
(I+3V)
(I+3V)
(TE)
1
36
25
24
13
15
20
37
48
45
40
30
35
5
1012
TP502 (I+3V)
TP503 (IOP)
MD BOARD (SIDE B)
digital voltmeter
KMS260B
27X40
B0825
B0825
lOP=82.5 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/3.3 (
lOP (mA) = Digital voltmeter reading (mV)/3.3 (
Ω
)
(Optical pick-up label)