10. Press the NO/CANCEL button to display “LDPWR
CHECK” and stop the laser emission.
(The NO/CANCEL button is effective at all times to stop
the laser emission)
(The NO/CANCEL button is effective at all times to stop
the laser emission)
Note 1: After step 9, each time the
YES/ENTER
button is pressed, the
display will be switched “LD 0.7 mW $
”, “LD 6.2 mW $
”,
and “LD WP
$
”. Nothing needs to be performed here.
(
= correction)
KMS260B
27X40
B0825
B0825
lOP=82.5 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/3.3 (
lOP (mA) = Digital voltmeter reading (mV)/3.3 (
Ω
)
(Optical pick-up label)
9. EF BALANCE ADJUSTMENT
Adjusting Procedure:
1. Connect an oscilloscope to TP504 (TE) and TP506 (VC) on
1. Connect an oscilloscope to TP504 (TE) and TP506 (VC) on
the MD board.
2. Load a disc (any available on the market). (Refer to Note 1)
3. Press the M button to move the optical pick-up outside the
3. Press the M button to move the optical pick-up outside the
pit.
4. Turn the JOG dial to display “EFBAL ADJUST”.
5. Press the YES/ENTER button to display “EFB = MO-R”.
5. Press the YES/ENTER button to display “EFB = MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
spindle (S) servo ON)
6. Turn the JOG dial so that the waveform of the oscilloscope be
comes the specified value.
(When the JOG dial is turned, the
(When the JOG dial is turned, the
of “EFB =
” changes
and the waveform changes ) In this adjust-ment, wave form var
ies at intervals of approx. 2 %. Adjust the waveform so that the
specified value is satisfied as much as possible.
(Read power traverse adjustment)
ies at intervals of approx. 2 %. Adjust the waveform so that the
specified value is satisfied as much as possible.
(Read power traverse adjustment)
7. Press the YES/ENTER button and save the result of adjust-
ment to the non-volatile memory. (“EFB = SAVE” will be
displayed for a moment. Then “EFB = MO-W” will be dis-
played)
displayed for a moment. Then “EFB = MO-W” will be dis-
played)
8. Turn the JOG dial so that the waveform of the oscilloscope be
comes the specified value.
(When the JOG dial is turned, the
(When the JOG dial is turned, the
of “EFB-
” changes and
the waveform changes) In this adjustment, waveform varies at
intervals of approx. 2%. Adjust the waveform so that the speci-
fied value is satisfied as much as possible.
(Write power traverse adjustment)
intervals of approx. 2%. Adjust the waveform so that the speci-
fied value is satisfied as much as possible.
(Write power traverse adjustment)
Note 1:
Data will be erased during MO reading if a recorded
disc is used in this adjustment.
Note 2:
If the traverse waveform is not clear, connect the
oscilloscope as shown in the following figure so that
it can be seen more clearly.
it can be seen more clearly.
C521
C526
L509
5
17
C519
C520 C522
R519
R518
R533
R531
R535
IC502
R524
R532
R525
R540
R542
R5
4
C546
R538
C550
TP505
(RF)
TP506
(VC)
TP504
(TE)
36
25
24
20
37
40
30
35
MD BOARD
(SIDE B)
Ω
oscilloscope
(DC range)
(DC range)
Connection:
C521
C526
L509
5
17
C519
C520 C522
R519
R518
R533
R531
R535
IC502
R524
R532
R525
R540
R542
R5
4
C546
R538
C550
TP505
(RF)
TP506
(VC)
TP504
(TE)
36
25
24
20
37
40
30
35
[MD BOARD]
(SIDE B)
(SIDE B)
oscilloscope
(DC range)
(DC range)
A
B
VC
Specification : A = B
Traverse Waveform
A
B
VC
Specification : A = B
Traverse Waveform
Specified Value:
Laser power meter reading : 7.0
Laser power meter reading : 7.0
±
0.2 mW
Digital voltmeter reading : Value on the optical pick-up label
±
10%