SRF-M37 - Sony Audio Service Manual (repair manual). Page 5

Read Sony SRF-M37 Service Manual online

5
SRF-M37
SECTION  3
ADJUSTMENTS
Setting:
BAND switch: AM
Connection:
For AM frequency coverage adjustment and FM frequency coverage check.
AM Section
digital
voltmeter
TP10 (VT)
Connection:
AM RF signal 
generator
30% amplitude modulation by 
400 Hz signal.
Output level: as low as possible
Put the lead-wire
antenna close to 
the set.
level meter
set
headphone jack (
i
)
16 
+
FM Section
FM RF signal
generator
22.5 kHz frequency deviation 
by 400 Hz signal.
Output level: as low as possible
0.01 
µ
F
TP12 (ANT)
Setting:
BAND switch:
FM
FM SENS switch: DX
Connection:
Adjustment Location
TP10
(VT)
TP12
(ANT)
MAIN  BOARD
  
MAIN  BOARD
  
IC2
IC1
(Conductor side)
CT2
L3
AM TRACKING
Adjustment
L4
AM FREQUENCY 
COVERAGE Adjustment
(Component side)
CT1
L1
FM TRACKING
Adjustment
AM FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a reading on digital voltmeter.
L4
530 kHz
1.3V 
± 0.1V
  Confirm
1,710 kHz
8.1V 
± 0.3V
AM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
CT2
1480 kHz
L3
590 kHz
FM FREQUENCY  COVERAGE  CHECK
Check a reading on digital voltmeter.
  Confirm
87.5 MHz
6.9V 
± 0.3V
  Confirm
108.0 MHz
12.1V 
± 0.3V
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
CT1
108.0 MHz
L1
87.5 MHz