NWZ-E353, NWZ-E354, NWZ-E355 - Sony Audio Service Manual (repair manual). Page 4

Read Sony NWZ-E353 / NWZ-E354 / NWZ-E355 Service Manual online

NWZ-E353/E354/E355
4
ABOUT  THE  HANDLING  OF  THE  BATTERY  ASSY 
(BAT1)
When the battery assy (BAT1) is removed, insulate the end of wire 
by a tape etc. to prevent short-circuited of the wire part of battery 
assy (BAT1).
battery assy (BAT1)
wire
wire
Wrap by the tape etc. and 
insulate the end of wire.
NOTE  THE  COMPLETE  EMMC  BOARD  REPLACING
When the complete EMMC board is replaced, process it according 
to the following.
1.  Destination setting
1-1. Outline
The destination code corresponding to each region must be in-
stalled into the EMMC board with the destination setting tool.
• EMMC board
Model
Capacity
Part No. of 
complete EMMC 
board
Pre-installed 
destination 
code
NWZ-E353
4GB
9-885-147-27
CEW
NWZ-E354
8GB
9-885-147-28
CEW
NWZ-E355
16GB
9-885-147-29
CEW
• Destination code
Model
Area
Destination 
code
Remark
NWZ-E353/
E354/E355
USA
U2
Canada
CA
Europe
CEW
CEV
India
IN
South 
Africa
IN
Please use the desti-
nation code, IN
1-2. Preparation
Note 1: Please use this Tool in Windows XP or later.
Note 2: Please install Windows Media Player 11 or later to make the unit 
recognize as MTP.
Note 3: Confi rm the method of obtaining the destination setting tool to the 
service headquarters.
Procedure:
1.  Unzip the destination setting tool to get “NWZE35XE45X_
Dest_Setting” folder.
2.  There are the three folders if you open “NWZE35XE45X_
DEST_Setting” folder.
3.  Copy the three folders in step 2 under C Drive.
Remark: Above folders in step 2 can be saved anywhere as long as the 
folder path is with English (one byte character).
Described with the example that “the folders were saved under 
C Drive” on this service manual.
One point: The destination setting tool for each series is stored as below.
Folder name
Folder name
Updater fi les
NWZ-E35X
WMT_CA
updating-mtp.bat etc.
WMT_CEV
updating-mtp.bat etc.
WMT_CEW
updating-mtp.bat etc.
WMT_IN
updating-mtp.bat etc.
WMT_U2
updating-mtp.bat etc.
1-3.  How to use the destination setting tool
Note 1: Please use this tool after closing other application software.
Will be described with below conditions as an example.
Model: NWZ-E353/E354/E355
Destination: CEW
Procedure:
1.  Turn on power of the WALKMAN, and connect it to PC.
2.  Start the command prompt application software, and change 
the folder pass to your desired folder (Example: c:\NWZE35X\
WMT_CEW).
3.  Input “updating-mtp” and press the Enter key on PC.
4.  If the following message is displayed, input “y” and press the 
Enter key on PC.
Note 2: When the Enter key on PC is pressed, the WALKMAN is format-
ted.
MTP F/W Update will start.
The WALKMAN unit reboots automatically after updating.
Before starting this program, close other application such 
as WMP, Napster and Rhapsody etc.
Does this program run? (y/n)
Ver. 1.1
Page of 30
Display