HCD-GX8000/RG77
 PANEL BOARD  IC601  MB90M407PF-G-114-BND (FLUORESCENT INDICATOR TUBE DRIVER, KEY CONTROL)
Pin No.
Pin Name
I/O
Description
1 to 10
P1 to P10
O
Segment drive signal output to the fluorescent indicator tube
11
VSS-IO
Ground terminal (for I/O port)
12 to 22
P11 to P21
O
Segment drive signal output to the fluorescent indicator tube
23
VDD-FIP
Power supply terminal (+3.3V) (for fluorescent indicator tube)
24 to 41
P22 to P39
O
Segment drive signal output to the fluorescent indicator tube
42
VSS-IO
Ground terminal (for I/O port)
43, 44
P40, P41
O
Segment drive signal output to the fluorescent indicator tube
45 to 47
NO-USE
Not used
48
VKK
Power supply terminal (–33V) (for fluorescent indicator tube)
49 to 51
MD0 to MD2
I
Setting terminal for the CPU operational mode
52
LED-TAPE
O
LED drive signal output of the TAPE A/B    “H”: LED on
53
LED-TUNER
O
LED drive signal output of the TUNER/BAND    “H”: LED on
54
LED-MD-VIDEO
O
LED drive signal output of the MD (VIDEO)    “H”: LED on
55
LED-CD
O
LED drive signal output of the CD    “H”: LED on
56
LED-GAME
O
LED drive signal output of the GAME    “H”: LED on
57
LED-DISC1
O
LED drive signal output of the DISC1    “H”: LED on
58
LED-DISC2
O
LED drive signal output of the DISC2    “H”: LED on
59
LED-DISC3
O
LED drive signal output of the DISC3    “H”: LED on
60
I2C-DATA
I/O
Communication data bus with the system controller
61
I2C-CLOCK
I/O
 
Communication data reading clock signal input or transfer clock signal output with the system
controller
62
AVCC
Power supply terminal (+3.3V) (for A/D conversion)
63
AVSS
Ground terminal (for A/D conversion)
64 to 66
KEY0 to KEY2
I
Key input terminal (A/D input)
67 to 72
BPF0 to BPF5
I
Spectrum analyzer drive signal input from the spectrum analyzer band-pass filter
73
ALL-BAND
I
Spectrum analyzer drive signal input from the spectrum analyzer band-pass filter
74
LED-REC
O
LED drive signal output of the REC PAUSE/START    “H”: LED on
75, 76
NO-USE
Not used
77
RESET
I
System reset signal input from the system controller    “L”: reset
78
SOFT-TEST
O
Output terminal for the software test
79
VOLUME-B
I
Jog dial pulse input from the rotary encoder (B phase input)
80
VOLUME-A
I
Jog dial pulse input from the rotary encoder (A phase input)
81
VSS-CPU
Ground terminal (for CPU)
82
X0
O
System clock output terminal (4 MHz)
83
X1
I
System clock input terminal (4 MHz)
84
VCC-CPU
Power supply terminal (+3.3V) (for CPU)
85
NO-USE
Not used
86 to 100
1G to 15G
O
Grid drive signal output to the fluorescent indicator tube
Page of 71
Display

Click on the first or last page to see other HCD-GX8000 / HCD-RG77 service manuals if exist.