IC  PIN  FUNCTION  DESCRIPTION
 MAIN BOARD  IC501 M30620MCN-A09FP (SYSTEM CONTROLLER (CD MECHANISM CONTROL))
Pin No.
Pin Name
I/O
Description
1
NO-USE
Not used
2
STEREO
I
FM stereo detection signal input from the tuner unit    “L”: stereo
3
TUNED
I
Tuning detection signal input from the tuner unit    “L”: tuned
4
SIRCS
I
Remote control signal input
5 to 7
SUR1 to SUR3
O
Surround signal processor control signal output terminal    Not used
8, 9
GND
Ground terminal
10
XC-IN
I
Sub system clock input terminal (32.768 kHz)
11
XC-OUT
O
Sub system clock output terminal (32.768 kHz)
12
RESET
I
System reset signal input from the reset signal generator    “L”: reset
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
13
X-OUT
O
Main system clock output terminal (16 MHz)
14
VSS
Ground terminal
15
X-IN
I
Main system clock input terminal (16 MHz)
16
VCC
Power supply terminal (+3.3V)
17
NMI
I
Non-maskable interrupt input terminal
18
NO-USE
Not used
19
SCOR
I
Subcode sync (S0+S1) detection signal input from the digital signal processor
20
AC-CUT
I
AC off detection signal input from the reset signal generator    “L”: AC cut checked
21
ST-MUTE
O
Tuner muting on/off control signal output    “H”: muting on
22
ST-CE
O
PLL chip enable signal output to the tuner unit
23
ST-DOUT
O
PLL serial data output to the tuner unit
24
PWM3
O
RFDC PWM signal output to the RF amplifier (for CD-RW)
25
ST-DIN
I
PLL serial data input from the tuner unit
26
PWM2
O
PWM signal output to the RF amplifier (for CD-RW)
27
ST-CLK
O
PLL serial data transfer clock signal output to the tuner unit
28
PWM1
O
Focus servo drive PWM signal output to the RF amplifier (for CD-RW)
29
IIC-CLK
I/O
Communication data reading clock signal input or transfer clock signal output with the fluorescent
indicator tube driver
30
IIC-DATA
I/O
Communication data bus with the fluorescent indicator tube driver
31
TXD1
Not used
32
SQ-DATA
I
Subcode Q data input from the digital signal processor
33
SQ-CLK
O
Subcode Q data reading clock signal output to the digital signal processor
34
SENS
I
Internal status detection monitor input from the digital signal processor
35
CD-DATA
O
Serial data output to the digital signal processor
36
XLT
O
Serial data latch pulse output to the digital signal processor
37
CD-CLK
O
Serial data transfer clock signal output to the digital signal processor
38
CD-POWER
O
Power on/off control signal output for the CD section   “H”: power on
39
CLOCK-OUT
O
Clock (32.768 kHz) signal output terminal (for test mode)
40
LD ON
O
Laser diode on/off control signal output to the RF amplifier    “L”: laser diode on
41
GC RESET
I
Reset signal output to the fluorescent indicator tube driver    “L”: reset
42
NO-USE
Not used
43
XRST
O
Reset signal output to the digital signal processor and motor/coil driver    “L”: reset
44
LOAD-IN
O
Turn motor drive signal output
45
LOAD-OUT
O
Turn motor drive signal output
46
OPEN-SW
I
Disc tray open detection signal input terminal    “L”: disc tray open
47
CLOSE-SW
I
Disc tray close detection signal input terminal    “L”: disc tray close