Read Sony HCD-ESX6 / HCD-ESX8 / HCD-ESX9 Service Manual online
HCD-ESX6/ESX8/ESX9
14
SECTION 3
ESX TEST MODE
[PANEL TEST MODE]
• This mode is used to check the liquid crystal display, LEDs,
• This mode is used to check the liquid crystal display, LEDs,
keys, [VOLUME] jog, model, destination and software
version.
version.
Procedure:
1. Press [FUNCTION] button and [BASS BAZUCA] button
simultaneously and hold 3 seconds.
2. All LEDs and segments of liquid crystal display will light up.
3. In the Panel Test Mode, when you want to enter to the
3. In the Panel Test Mode, when you want to enter to the
software version display mode, press [+] button. The model
information appears on the fl uorescent indicator tube.
information appears on the fl uorescent indicator tube.
•
“ESX0” is shown for MHC-ESX6.
•
“ESX1” is shown for MHC-ESX8.
•
“ESX2” is shown for MHC-ESX9.
Press
[+] button again to view the destination information.
4. During the destination information display, press [+]
button. Each time [+] button is pressed, the fl uorescent
indicator tube shows the version of each category software
in the following sequence: SC, MTK, OPU, UI, PF, SYS, CD,
CMA, CMB, ST, TA, TAS, TM and return back to model
information display.
indicator tube shows the version of each category software
in the following sequence: SC, MTK, OPU, UI, PF, SYS, CD,
CMA, CMB, ST, TA, TAS, TM and return back to model
information display.
5. When [FUNCTION] button is pressed while the version
numbers are being displayed except model and destination,
the date of the software creation appears. When [FUNCTION]
button is pressed again, the display returns to the software
version display.
the date of the software creation appears. When [FUNCTION]
button is pressed again, the display returns to the software
version display.
6. Press [–] button, the key check mode is activated.
7. In the key check mode, the liquid crystal display will displays
7. In the key check mode, the liquid crystal display will displays
“K 0 V0”.
Each time a button is pressed, “K” value increases. However,
once a button has been pressed, it is no longer taken into
account.
once a button has been pressed, it is no longer taken into
account.
“V” value increases in the manner of 0, 1, 2, 3 ... if [MASTER
VOLUME] knob is turned clockwise, or it decreases in the
manner of 0, 9, 8, 7 ... if [MASTER VOLUME] knob is turned
counterclockwise.
VOLUME] knob is turned clockwise, or it decreases in the
manner of 0, 9, 8, 7 ... if [MASTER VOLUME] knob is turned
counterclockwise.
8. When [] button is pressed after all LEDs and segments in
liquid crystal display light up, alternate segments in liquid
crystal display and LEDs would light up. If you press []
button again, another half of alternate segments in liquid
crystal display and LEDs would light up. Pressing [] button
again would cause all segments in liquid crystal display and
LEDs light up. Pressing [] button again would turn off all
segments in fl uorescent indicator tube and all LEDs.
crystal display and LEDs would light up. If you press []
button again, another half of alternate segments in liquid
crystal display and LEDs would light up. Pressing [] button
again would cause all segments in liquid crystal display and
LEDs light up. Pressing [] button again would turn off all
segments in fl uorescent indicator tube and all LEDs.
9. To release from this mode, press the buttons in the same
manner as step 1, or disconnect the power cord.
[USER RESET]
• The user reset clears all data including preset data stored in
• The user reset clears all data including preset data stored in
the data fl ash to initial conditions exclude history mode data.
Procedure:
1. Press
[&/1] button to turn on the system.
2. Press [FUNCTION] button and [&/1] button simultaneously
for 3 seconds.
3. “RESET” appears on the liquid crystal display. After that,
the liquid crystal display becomes blank for a while, and the
system is reset.
system is reset.
[COLD RESET]
• The cold reset clears all data including preset data stored in
• The cold reset clears all data including preset data stored in
the data fl ash to initial conditions included history mode data.
Execute this mode when returning the set to the customer.
Execute this mode when returning the set to the customer.
Procedure:
1. Press
[&/1] button to turn on the system.
2. Press [ENTER] button and [&/1] button simultaneously for 3
seconds.
3. “COLD RST” appears on the liquid crystal display. After
that, the liquid crystal display becomes blank for a while, and
the system is reset.
the system is reset.
[CD SHIP MODE (WITH MEMORY CLEAR)]
• This mode moves the optical pick-up to the position durable
• This mode moves the optical pick-up to the position durable
to vibration and clears all data including preset data stored in
the data fl ash to initial conditions during the next AC-In. Use
this mode when returning the set to the customer after repair.
the data fl ash to initial conditions during the next AC-In. Use
this mode when returning the set to the customer after repair.
Procedure:
1. Press
[\/1] button to turn on the system.
2. Press [FUNCTION] button to select CD function.
3. Press [OPTIONS] button and [TUNING –] button simultaneously
3. Press [OPTIONS] button and [TUNING –] button simultaneously
for 3 seconds. The system turns off automatically.
4. A message “MECHA LOCK” is displayed on the liquid
crystal display and the CD ship mode is set.
[CD TRAY LOCK MODE]
• This mode let you lock the disc tray. When this mode is
• This mode let you lock the disc tray. When this mode is
activated, the disc tray will not open when [Z] button is
pressed. The message “LOCKED” will be displayed on the
liquid crystal display. This mode only applied when there is
disc(s) on the tray.
pressed. The message “LOCKED” will be displayed on the
liquid crystal display. This mode only applied when there is
disc(s) on the tray.
Procedure:
1. Press
[\/1] button to turn on the system.
2. Press [FUNCTION] button to select CD function.
3. Press
3. Press
[] button and [REC TO USB] button simultaneously
and hold down until “LOCKED” or “UNLOCKED” displayed
on the liquid crystal display (around 5 seconds).
on the liquid crystal display (around 5 seconds).
[CDM AGING MODE]
• This mode is used for CDM aging.
• This mode is used for CDM aging.
Procedure:
1. Press
[\/1] button to turn on the system.
2. Press [FUNCTION] button to select CD function.
3. Open the disc tray, insert a disc and close the tray.
4. Press [REC TO USB] button and [EQ +] button simultaneously
3. Open the disc tray, insert a disc and close the tray.
4. Press [REC TO USB] button and [EQ +] button simultaneously
for 3 seconds.
5. The liquid crystal display displays Aging Display
“xxxxyyyy”.
“xxxx” represents the error counter
(Maximum Value of “xxxx” = 9999)
“yyyy” represents the cycle counter
(Maximum Value of “yyyy” = 9999)
6. Press [TUNING + M >] or [TUNING – .m] to
search for Aging History Error Display.
The liquid crystal display displays “Mx” for 2 seconds to
indicate selected history number. Then, liquid crystal display
displays “E1E2E3E4”.
indicate selected history number. Then, liquid crystal display
displays “E1E2E3E4”.
x: error history number
E1: Loading sequence JCP high
E2: Loading sequence JCP low
E3: Loading operation JCP
E4: Cam position operation JCP
7. Press
[] to Aging Display
• To release from CDM Aging Mode.
To release from this mode, press [\/1] button or perform COLD
RESET operation.
To release from this mode, press [\/1] button or perform COLD
RESET operation.
Click on the first or last page to see other HCD-ESX6 / HCD-ESX8 / HCD-ESX9 service manuals if exist.