PZ-50HV2E (serv.man8). Adjustment procedures - Sharp TV Service Manual (repair manual). Page 4

Read Sharp PZ-50HV2E (serv.man8) Service Manual online

19
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
3. Adjustment and Setting Item of the Plasma Display
Display example of the eleventh page
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
MNTR
1
1 / 1 3
PUT1 No S I G
N
I
V5 0
0 2
WB
MNTR V6 0
0 1
WB
MNTR PC
0 1
WB
MNTR R H
2 5 5
I GH1
MNTR R H
2 5 5
I GH2
MNTR G H
2 5 5
I GH2
MNTR B H
2 5 4
I GH2
MNTR G H
2 5 5
I GH1
MNTR B H
2 5 4
I GH1
MNTR R L
5 1 0
OW1
MNTR G L
5 0 9
OW1
MNTR B L
5 1 2
OW1
MNTR R L
5 1 0
OW2
MNTR G L
5 1 1
OW2
MNTR B L
5 1 2
OW2
No.
Item
Adjustable Range
Shipping Setting
Storage Place
1
PDP_W/B table selection at VIDEO 50Hz
1 or 2
2
PDP
2
PDP_W/B table selection at VIDEO 60Hz
1 or 2
1
PDP
3
PDP_W/B table selection at PC
1 or 2
1
PDP
4
RED_GAIN of PDP_W/B table 1
0 to 255
Factory adjustment value
PDP
5
GREEN_GAIN of PDP_W/B table 1
0 to 255
Factory adjustment value
PDP
6
BLUE_GAIN of PDP_W/B table 1
0 to 255
Factory adjustment value
PDP
7
RED_OFS of PDP_W/B table 1
0 to 999
Factory adjustment value
PDP
8
GREEN_OFS of PDP_W/B table 1
0 to 999
Factory adjustment value
PDP
9
BLUE_OFS of PDP_W/B table 1
0 to 999
Factory adjustment value
PDP
10
RED_GAIN of PDP_W/B table 2
0 to 255
Factory adjustment value
PDP
11
GREEN_GAIN of PDP_W/B table 2
0 to 255
Factory adjustment value
PDP
12
BLUE_GAIN of PDP_W/B table 2
0 to 255
Factory adjustment value
PDP
13
RED_OFS of PDP_W/B table 2
0 to 999
Factory adjustment value
PDP
14
GREEN_OFS of PDP_W/B table 2
0 to 999
Factory adjustment value
PDP
15
BLUE_OFS of PDP_W/B table 2
0 to 999
Factory adjustment value
PDP
Caution in the PDP W/B (No.4 to 15) adjustment:
Adjustment value is reflected without relation in input signal during adjustment to the actual PDP.
For example, when operate a adjustment value of [MNTR HIGH1] during PAL input, switch to the adjustment value operation of W/B table 1 
while displaying PAL in the actual PDP.
This is temporary.
After adjustment, it becomes the W/B table 2 operation in the PAL input after restarted in the normal mode. It becomes an operation of the W/B 
table 1 adjustment value after adjustment in the NTSC input.
As for the above example, table selection (No. 1 and 2) becomes the shipping setting.
 : Be careful so that there is the case that page constitution is different.
Page of 19