LC-65XS1E (serv.man3). Adjustment - Sharp TV Service Manual (repair manual). Page 19

Read Sharp LC-65XS1E (serv.man3) Service Manual online

LC-52XS1E/RU/LC-65XS1E/RU
3 – 19
3. Set value of the Public Mode
• Each set value in the PUBLIC Mode is initialized when the factory setting is applied.
(The setting of the PUBLIC MODE Flag in the process adjustment mode screen is not changed.)
4. Basic operation in the Public Mode
1. Key Operation
2.
5. Operation after “RESET”
Select “RESET” in the PUBLIC Mode, and it operates as follows when it is executed (refer to the basic operation).
• The set contents in the PUBLIC mode are initialized.
•  It does not exit the PUBLIC mode.
• PUBLIC MODE Flag does not change. (It is not set to OFF.)
[8] Setting items (* Item names and selective items are expressed in English.)
1. Power ON Fixed (POWER ON FIXED)
If the power button is pressed in the ordinary mode when set to “FIXED”, the caution is displayed for 5 seconds.
Key Name
Mode
Key Function
Volume (+/-) or Cursor 
/
Change or execution of the set value.
Channel 
/
 or Cursor 
/
   
Movement to the selected item.
Decision (OK) 
Execution (Used by the items “Execution” and “RESET”.)
PUBLIC Mode R/C 
Ordinary operation mode: It enters the PUBLIC Mode.
PUBLIC MODE Flag is set to “ON”.
PUBLIC Mode: It exits the PUBLIC Mode.
PUBLIC MODE Flag does not change.
Any set item in PUBLIC Mode is not initialized.
Public Mode
Changeable value
POWER ON FIXED 
 [VARIABLE]
 [VARIABLE]/[FIXED ALL]/[FIXED_BODYKEY]/[PC RESPOND]
SHUT DOWN MODE 
 [NORMAL]
[NORMAL]/[QUICK]
MAXIMUM VOLUME 
 [60]
[0-60]
VOLUME FIXED 
 [VARIABLE]
 [VARIABLE]/[FIXED]/[AC CTRL]/[AC/RC CTRL]
VOLUME FIXED 
LEVEL
 [20]
 [gray out]
RC BUTTON 
 [RESPOND]
 [RESPOND]/[NO RESPOND]/[LIMITED]
PANEL BUTTON 
 [RESPOND]
 [RESPOND]/[NO RESPOND]
MENU BUTTON 
 [RESPOND]
 [RESPOND]/[NO RESPOND]
AV POSITION FIXED 
 [VARIABLE]
 [VARIABLE]/[FIXED]
ON SCREEN DISPLAY 
 [YES]
 [YES]/[NO]/[LIMITED]
INPUT MODE START 
 [NORMAL]
 [NORMAL]/[TVD(001TV)]/[INPUT1]/[INPUT2]/[INPUT3]/[INPUT8]/[HDMI1]/[HDMI2]/[HDMI3]/[PC]
INPUT MODE FIXED
 [VARIABLE]
 [gray out]
LOUD SPEAKER 
 [ON]
 [ON]/[OFF]
RC PATH THROUGH 
 [OFF]
 [ON:TV RCE]/[OFF:TV RCE]
232C POWON 
 [DISABLE]
 [DISABLE]/[ENABLE]
HOTELMODE  
[ON]
 
[ON]/[OFF]
RESET
EXECUTE
Selection 
“VARIABLE” or “FIXED” is selectable. (Loop is provided.)
Default “VARIABLE”
Function
• When "FIXED" is set, “Power ON/Standby Key” of the main unit and R/C is disabled.
Keys disabled when not set to Default • OFF_TIMER (SLEEP)
 Remarks 
The function does not work for any other standby factors (see below).
• No operation OFF
• No signal OFF (including the power management)