Read Sharp LC-37GE1E (serv.man6) Service Manual online
LC-37GE1E
6 – 8
8/12
[M GAMMA 1-3]
1
M GAMMA R 1
106
W/B adjustment, gradation 1R adjustment value
2
M GAMMA G 1
106
W/B adjustment, gradation 1G adjustment value
3
M GAMMA B 1
106
W/B adjustment, gradation 1B adjustment value
4
M GAMMA R 2
271
W/B adjustment, gradation 2R adjustment value
5
M GAMMA G 2
271
W/B adjustment, gradation 2G adjustment value
6
M GAMMA B 2
271
W/B adjustment, gradation 2B adjustment value
7
M GAMMA R 3
448
W/B adjustment, gradation 3R adjustment value
8
M GAMMA G 3
448
W/B adjustment, gradation 3G adjustment value
9
M GAMMA B 3
448
W/B adjustment, gradation 3B adjustment value
10
M GAMMA WRITE
off/on
EEP writing of adjustment values
9/12
[M GAMMA 4-6]
1
M GAMMA R 4
623
W/B adjustment, gradation 4R adjustment value
2
M GAMMA G 4
623
W/B adjustment, gradation 4G adjustmnet value
3
M GAMMA B 4
623
W/B adjustment, gradation 4B adjustment value
4
M GAMMA R 5
800
W/B adjustment, gradation 5R adjustment value
5
M GAMMA G 5
800
W/B adjustment, gradation 5G adjustment value
6
M GAMMA B 5
800
W/B adjustment, gradation 5B adjustment value
7
M GAMMA R 6
958
W/B adjustment, gradation 6R adjustment value
8
M GAMMA G 6
958
W/B adjustment, gradation 6G adjustment value
9
M GAMMA B 6
958
W/B adjustment, gradation 6B adjustment value
10
M GAMMA WRITE
off/on
EEP writing of adjustment values
10/12
[ETC]
1
EEP CLEAR
off/on
Clear of process adjustment EEP value
2
EEP CLEAR B
off/on
Clear of process adjustment value of B_mode.
3
STANDBYCAUSE RESET
off/on
Reset of STANDBY CAUSE
4
AUTO INSTALLATION SW
0/1
1:* * * 0: * * *
5
OPTION
0
6
COUNTRY
AUTO/EURO/UK
Destination setting
7
L ERR RESET
0
LAMP ERR RESET Initialization of L_ERR
8
L ERR STOP
0/1
LAMP ERR Inhibit L_ERR detection.
9
DTV CLR
off/on
Clear of DTV unit.
10
I2C-OFF
off/on
STOP of I2C DATA execution
11/12
[LCD]
1
OSC FREQ50
1094
INVERTER drive frequency setting
2
OSC FREQ60
1094
INVERTER drive frequency setting
3
PWM FREQ50
423
Frequency setting for INVERTER dimmer
4
PWM FREQ60
423
Frequency setting for INVERTER dimmer
5
VCOM ADJ
64
12/12
[LCD TESTPATTERN]
1
PATTERN
0
Display LCD test pattern.