LC-37GE1E (serv.man6). Adjustment Proceedures - Sharp TV Service Manual (repair manual). Page 11

Read Sharp LC-37GE1E (serv.man6) Service Manual online

LC-37GE1E
6 – 11
9. Initialization to factory settings
CAUTION: When the factory settings have been made,  all user setting data,  including the channel settings,  are initialized. (The adjustments done in
the adjustment process mode are not initialized.) Keep this in mind when initializing these settings.
10. Lamp error detection
1. Function
This LCD color TV set incorporates a lamp error detection feature that automatically turns off the power for safety under abnormal lamp or lamp
circuit conditions. If by any chance anything is wrong with the lamp or lamp circuit or if the lamp error detection feature is activated for some rea-
son,  the following will result.
<1> The power is interrupted in about 6 seconds after it is turned on.
(The power LED on the front of the TV set turns red from green and keeps blinking in red:  ON for 250 ms and OFF for 1 sec).
<2> If the above phenomenon <1> occurs 5 times consecutively, it becomes impossible to turn on the power. (The power LED remains red).
2. Measures
<1> Checking with lamp error detection OFF 
Enter the adjustment process mode, referring to "3. Entering and exiting the adjustment process mode." 
If there is a problem with the lamp or lamp circuit,  the lamp will go out. (The power LED is green.)
Then,  you can check the operation to see if the lamp and lamp circuit are in trouble.
<2> Resetting the lamp error count
After the lamp and lamp circuit are found out of trouble, reset the lamp error count. If a lamp error is detected five consecutive times,  the power
cannot be turned on. Using the cursor (UP/DOWN) key, move to the cursor to [L ERR RESET],  Line 6 on adjustment process mode service page
10/13. With the cursor (LEFT/RIGHT) keys,  select the [L ERR RESET] value. Finally press the “OK” keys to reset the value to "0".  Reset to "0 "
Table of contents of adjustment process mode Page 10/13
 
Adjustment point
Adjustment Conditions
Adjustment procedure
1
Factory setting
Forcibly turn off the 
power
(See to below caution)
•Enter  the adjustment process mode.
•Move the cursor to [Factory Init] on page 2/13
•Use the R/C 
key to select a region from [EURO/UK/ITALY/FRANCE/RUSSIA] and 
press the [OK] key.
“EXECUTING” appears and initialization starts 
After a  while, “OK” appears and the setting is complete.
NOTE: Never turn the power off during initialization.
The background appears green when succeeded,  and red when failed.
2
The following item are initialized in the factory setting.
1. User settings
2. Channel data (e.g. broadcast frequencies)
3. Maker option setting
4. Password data
After adjustments,  exit the adjustment process mode.
To exit the adjustment process mode,  unplug the AC power cord from the outlet to forcibly turn off the power.
When the power is turned off with the remote control, unplug the AC power cord and plug it back  in.
㵘㵘
[ETC]
㵘㵘
EEP CLEAR
off
㵘㵘
EEP CLEAR B
off
㵘㵘
STANDBY CAUSE RESET
off
AUTO INSTALLATION SW
0
OPTION
0
㵘㵘
COUNTRY
EURO
㵘㸢
L ERR RESET
0
㵘㵘
L ERR STOP
0
㵘㵘
DTV CLR
off
㵘㵘
I2C-OFF
off
㵘㵘㵘
Resetting to "0"